Literature DB >> 9164151

Measurements of glomerular filtration in the intensive care unit are only a rough guide to renal function.

M Wells1, J Lipman.   

Abstract

An estimate of glomerular filtration rate (GFR) is important in intensive care units (ICUs) to individualize drug dosages, and for the early detection of acute renal failure (ARF). Creatinine clearance or calculations based on plasma creatinine are the most widely used indicators of GFR, but may be very inaccurate in critically ill patients. We have assessed the accuracy of predictions of GFR by creatinine clearance and plasma creatinine in critically ill patients with variable creatinine kinetics. This is a retrospective record review set in a 24-bed multidisciplinary ICU. Eighteen patient records (9 normal renal function, 9 with ARF-250 patient days) were evaluated. Creatinine clearance measured daily over an 8-hour period, plasma creatinine, creatinine production and 8-hourly urine output were recorded for each day of ICU stay. The discrepancy between measured creatinine clearance and creatinine clearance predicted by the Cockcraft-Gault equation was determined. The coefficient of variation (CV) for each of the contributing variables and the final inherent error for the estimation of GFR were determined. The difference between measured and predicted creatinine clearance was large (predicted GFR may be from 60 ml/min above to 70 ml/min below measured creatinine clearance). The mean CV for creatinine production was 28% and for 8-hourly urine output it was 34%. The estimation of GFR from creatinine clearance can be made at +/- 52% of the calculated value, whereas the estimation of GFR by Cockcraft-Gault is accurate at +/- 37% of the calculated value. Unstable creatinine kinetics from variable urine output and creatinine production in critically ill patients make accurate estimation of GFR impossible. While prediction methods have fewer inherent sources of error, plasma creatinine may be influenced by factors other than renal function. The use of prediction equations is as inaccurate as measured clearance in unstable ICU patients.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9164151

Source DB:  PubMed          Journal:  S Afr J Surg        ISSN: 0038-2361            Impact factor:   0.375


  9 in total

1.  Creatinine generation is reduced in patients requiring continuous venovenous hemodialysis and independently predicts mortality.

Authors:  Francis P Wilson; Jessica M Sheehan; Laura H Mariani; Jeffrey S Berns
Journal:  Nephrol Dial Transplant       Date:  2012-01-23       Impact factor: 5.992

Review 2.  Augmented renal clearance: implications for antibacterial dosing in the critically ill.

Authors:  Andrew A Udy; Jason A Roberts; Robert J Boots; David L Paterson; Jeffrey Lipman
Journal:  Clin Pharmacokinet       Date:  2010       Impact factor: 6.447

3.  New colistin population pharmacokinetic data in critically ill patients suggesting an alternative loading dose rationale.

Authors:  N Grégoire; O Mimoz; B Mégarbane; E Comets; D Chatelier; S Lasocki; R Gauzit; D Balayn; P Gobin; S Marchand; W Couet
Journal:  Antimicrob Agents Chemother       Date:  2014-09-29       Impact factor: 5.191

4.  Pharmacokinetics and pharmacodynamics of meropenem in elderly chinese with lower respiratory tract infections: population pharmacokinetics analysis using nonlinear mixed-effects modelling and clinical pharmacodynamics study.

Authors:  Qing-tao Zhou; Bei He; Chao Zhang; Suo-di Zhai; Zhen-ying Liu; Jie Zhang
Journal:  Drugs Aging       Date:  2011-11-01       Impact factor: 3.923

5.  Assessing glomerular filtration rate in hospitalized patients: a comparison between CKD-EPI and four cystatin C-based equations.

Authors:  Alfonso Segarra; Judith de la Torre; Natalia Ramos; Augusto Quiroz; Maria Garjau; Irina Torres; M Antonia Azancot; Montserrat López; Ana Sobrado
Journal:  Clin J Am Soc Nephrol       Date:  2011-08-18       Impact factor: 8.237

6.  Reduced production of creatinine limits its use as marker of kidney injury in sepsis.

Authors:  Kent Doi; Peter S T Yuen; Christoph Eisner; Xuzhen Hu; Asada Leelahavanichkul; Jürgen Schnermann; Robert A Star
Journal:  J Am Soc Nephrol       Date:  2009-04-23       Impact factor: 10.121

7.  Impact of creatinine production on the agreement between glomerular filtration rate estimates using cystatin C-derived, and 4- and 6-variable Modification of Diet in Renal Disease (MDRD), and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations.

Authors:  Esperanza F Hermida-Cadahia; Natalia Lampon; J Carlos Tutor
Journal:  Ups J Med Sci       Date:  2012-07-03       Impact factor: 2.384

Review 8.  Estimation of renal function in the intensive care unit: the covert concepts brought to light.

Authors:  Sham Sunder; Rajesh Jayaraman; Himanshu Sekhar Mahapatra; Satyanand Sathi; Venkata Ramanan; Prabhu Kanchi; Anurag Gupta; Sunil Kumar Daksh; Pranit Ram
Journal:  J Intensive Care       Date:  2014-05-07

9.  Augmented renal clearance in Japanese intensive care unit patients: a prospective study.

Authors:  Yasumasa Kawano; Shinichi Morimoto; Yoshito Izutani; Kentaro Muranishi; Hironari Kaneyama; Kota Hoshino; Takeshi Nishida; Hiroyasu Ishikura
Journal:  J Intensive Care       Date:  2016-10-03
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.