Literature DB >> 9163641

Is nitric oxide in exhaled air produced at airway or alveolar level?

C A Byrnes1, S Dinarevic, C Busst, A Bush, E A Shinebourne.   

Abstract

The aim of this study was to determine whether the nitric oxide (NO) measured in exhaled air is produced at airway or alveolar level. Exhaled NO was measured using a chemiluminescence analyser, and carbon dioxide (CO2 concentration using a Morgan capnograph in single exhalations in 12 healthy subjects (mean age 32 yrs; 6 males and 6 females). For each subject, five exhalations were made directly into the NO analyser and five were made through a T-piece system, which allowed measurement of expiratory flow rate. The peak NO levels measured via the T-piece system were 41.2 (SEM 10.8) parts per billion (ppb), significantly lower than direct levels 84.8 (14.0) ppb (p<0.001). The levels of NO tended to rise to an early peak and plateau, while the CO2 levels continued to rise to peak late in the exhalation. The mean times to reach peak NO levels were 32.2 s (direct) and 23.1 s (T-piece), which were significantly different from that of peak CO2 levels 50.5 s (direct) and 51.4 s (T-piece) (p<0.001). At peak NO level, the simultaneous CO2 level mean 4.9% (SEM 0.14)%, was significantly lower than the peak CO2 reached, 5.8 (0.21)% (p<0.001). We conclude that peak nitric oxide levels are dependent on measurement conditions. There are significant differences between the time to peak of carbon dioxide and nitric oxide. Therefore, most nitric oxide, unlike carbon dioxide, is produced in airways and not at alveolar level.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9163641     DOI: 10.1183/09031936.97.10051021

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  5 in total

Review 1.  Exhaled nitric oxide during exercise.

Authors:  A W Sheel; J Road; D C McKenzie
Journal:  Sports Med       Date:  1999-08       Impact factor: 11.136

2.  Influence of atmospheric nitric oxide concentration on the measurement of nitric oxide in exhaled air.

Authors:  M Corradi; A Pelizzoni; M Majori; A Cuomo; E de' Munari; A Pesci
Journal:  Thorax       Date:  1998-08       Impact factor: 9.139

3.  Effect of measurement conditions on measured levels of peak exhaled nitric oxide.

Authors:  C A Byrnes; S Dinarevic; C A Busst; E A Shinebourne; A Bush
Journal:  Thorax       Date:  1997-08       Impact factor: 9.139

4.  Nitric oxide synthesis in the lung. Regulation by oxygen through a kinetic mechanism.

Authors:  R A Dweik; D Laskowski; H M Abu-Soud; F Kaneko; R Hutte; D J Stuehr; S C Erzurum
Journal:  J Clin Invest       Date:  1998-02-01       Impact factor: 14.808

5.  Alveolar exhaled nitric oxide is elevated in hereditary hemorrhagic telangiectasia.

Authors:  Samir Gupta; Noe Zamel; Marie E Faughnan
Journal:  Lung       Date:  2008-10-24       Impact factor: 2.584

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.