Skin dose from radiotherapy X-ray beams: the influence of energy.

M J Butson1, J N Mathur, P E Metcalfe.   

Abstract

Skin-sparing properties of megavoltage photon beams are compromised by electron contamination. Higher energy beams do not necessarily produce lower surface and basal cell layer doses due to this electron contamination. For a 5 x 5 cm field size the surface doses for 6 MVp and 18 MVp X-ray beams are 10% and 7% of their respective maxima. However, at a field size of 40 x 40 cm the percentage surface dose is 42% for both 6 MVp and 18 MVp beams. The introduction of beam modifying devices such block trays can further reduce the skin-sparing advantages of high energy photon beams. Using a 10 mm perspex block tray, the surface doses for 6 MVp and 18 MVp beams with a 5 x 5 cm field size are 10% and 8%, respectively. At 40 x 40 cm, surface doses are 61% and 63% for 6 MVp and 18 MVp beams, respectively. This trend is followed at the basal cell layer depth. At a depth of 1 mm, 18 MVp beam doses are always at least 5% smaller than 6 MVp doses for the same depth at all field sizes when normalized to their respective Dmax values. Results have shown that higher energy photon beams produce a negligible reduction of the delivered dose to the basal cell layer (0.1 mm). Only a small increase in skin sparing is seen at the dermal layer (1 mm), which can be negated by the increased exit dose from an opposing field.

Mesh:

Year:  1997        PMID: 9153811

Source DB:  PubMed          Journal:  Australas Radiol        ISSN: 0004-8461


  4 in total

1.  Effect of a carbon fiber tabletop on the surface dose and attenuation for high-energy photon beams.

Authors:  Tülay P Meydanci; Gönül Kemikler
Journal:  Radiat Med       Date:  2008-11-22

2.  Surface buildup dose dependence on photon field delivery technique for IMRT.

Authors:  Shigeru Yokoyama; Peter L Roberson; Dale W Litzenberg; Jean M Moran; Benedick A Fraass
Journal:  J Appl Clin Med Phys       Date:  2004-04-01       Impact factor: 2.102

3.  An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements.

Authors:  Lukkana Apipunyasopon; Somyot Srisatit; Nakorn Phaisangittisakul
Journal:  J Radiat Res       Date:  2012-10-26       Impact factor: 2.724

4.  Skin dose during radiotherapy: a summary and general estimation technique.

Authors:  Stephen F Kry; Susan A Smith; Rita Weathers; Marilyn Stovall
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102