Literature DB >> 9151601

A clinical retrospective evaluation of FA/HA coated (Biocomp) dental implants. Results after 1 year.

M S Cune1, I P van Rossen, C de Putter, R P Wils.   

Abstract

In this retrospective clinical evaluation, the performance of loaded titanium implants with a bilayer bioactive surface coating of the relatively reactive hydroxylapatite (HA, outer layer) and the more stable fluorapatite (FA, inner layer) was evaluated. 98 consecutive patients were included in the study for a total of 354 implants, loaded by overdentures, fixed partial dentures and single tooth replacements. Statistical analyses revealed a cumulative probability of implant survival on a per patient basis of 94.5% (s.e. 2.7%), one year after implant installation. On implants that were lost parts of the bilayer FA/HA coating had vanished as a result of primary or secondary infection and subsequently epithelial down growth. Most complications were associated with implants placed in the maxilla. Periotest values (PTV) were generally high, indicating adequate osseointegration. The PTV's were statistically significantly less favorable in implants placed in the maxilla. The most favorable PTV's and gingival index scores were found around implants servicing overdentures. Marginal bone loss averaged approximately 2mm during the observation period. The amount of marginal bone loss corresponded with the distance from the neck of the implant to the first thread of the implant's cervical screw-section. It is concluded that, during the relatively short observation period, the FA/HA coated implants function adequately. However, in the absence of a direct implant-to-bone contact preceding implant loss, part of the FA/HA coating on the titanium implants generally dissolves.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9151601     DOI: 10.1034/j.1600-0501.1996.070407.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  2 in total

1.  Behaviour of MG-63 osteoblast-like cells on wood-based biomorphic SiC ceramics coated with bioactive glass.

Authors:  A de Carlos; J P Borrajo; J Serra; P González; B León
Journal:  J Mater Sci Mater Med       Date:  2006-06       Impact factor: 3.896

2.  Histomorphometric evaluation of implants coated with enamel or dentine derived fluoride-substituted apatite.

Authors:  Mehmet Kürkcü; Mehmet Emre Benlidayi; Serhat Ozsoy; Lütfiye Sevgi Ozyeğin; Faik Nuzhet Oktar; Cem Kurtoğlu
Journal:  J Mater Sci Mater Med       Date:  2007-06-19       Impact factor: 3.896

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.