Literature DB >> 9151181

Changes in bone mineral density around a stable uncemented total hip arthroplasty.

P Korovessis1, G Piperos, A Michael, A Baikousis, M Stamatakis.   

Abstract

Changes in bone mineral density (BMD) around the components of the Zweymueller total hip arthroplasty were measured, using dual energy X-ray absorptiometry, in 36 women who were operated on for primary osteoarthritis. Seven regions of interest were studied. No changes occurred around the screw socket and the greater trochanter: but there was a significant reduction of BMD, only when measured immediately after the operation at the lesser trochanter and at the distal femoral cortex lateral and medial to the tip of the stem. These changes were not related to the age of the patients. The reduction of BMD in the femur was mostly associated with areas where bone had been removed at operation. The press-fit fixation of the Zweymueller stem and the maintenance of its fixation with time did not induce further bone turnover around it. The absence of changes in bone mineral density was due to the relatively small amount of subchondral removed and to the continued stable fixation of the socket.

Entities:  

Mesh:

Year:  1997        PMID: 9151181      PMCID: PMC3615680          DOI: 10.1007/s002640050113

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  5 in total

1.  Densitometric evaluation of periprosthetic bone remodeling.

Authors:  Paolo Domenico Parchi; Valentina Cervi; Nicola Piolanti; Gianluca Ciapini; Lorenzo Andreani; Iacopo Castellini; Andrea Poggetti; Michele Lisanti
Journal:  Clin Cases Miner Bone Metab       Date:  2014-09

2.  Periprosthetic bone mineral density with a cementless triple tapered stem is dependent on daily activity.

Authors:  Shinya Hayashi; Takayuki Nishiyama; Takaaki Fujishiro; Noriyuki Kanzaki; Shingo Hashimoto; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2011-11-30       Impact factor: 3.075

3.  Primary stability of a shoulderless Zweymüller hip stem: a comparative in vitro micromotion study.

Authors:  Ralf Bieger; Tobias Freitag; Anita Ignatius; Heiko Reichel; Lutz Dürselen
Journal:  J Orthop Surg Res       Date:  2016-07-05       Impact factor: 2.359

4.  Comparisons of the surface micromotions of cementless femoral prosthesis in the horizontal and vertical levels: a network analysis of biomechanical studies.

Authors:  Bomin Wang; Qinghu Li; Jinlei Dong; Dongsheng Zhou; Fanxiao Liu
Journal:  J Orthop Surg Res       Date:  2020-07-31       Impact factor: 2.359

5.  Influence of Hydroxyapatite Coating for the Prevention of Bone Mineral Density Loss and Bone Metabolism after Total Hip Arthroplasty: Assessment Using 18F-Fluoride Positron Emission Tomography and Dual-Energy X-Ray Absorptiometry by Randomized Controlled Trial.

Authors:  Taro Tezuka; Naomi Kobayashi; Choe Hyonmin; Masatoshi Oba; Yushi Miyamae; Akira Morita; Yutaka Inaba
Journal:  Biomed Res Int       Date:  2020-02-22       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.