Literature DB >> 9151064

Hypothetical mortality risk associated with spiral tomography of the maxilla and mandible prior to endosseous implant treatment.

K Dula1, R Mini, J T Lambrecht, P F van der Stelt, P Schneeberger, G Clemens, H Sanderink, D Buser.   

Abstract

Radiation dose delivered from the SCANORA radiography unit during the cross-sectional mode for dentotangential projections was determined. With regard to oral implantology, patient situations of an edentulous maxilla and mandible as well as a single tooth gap in regions 16 and 46 were simulated. Radiation doses were measured between 0.2 and 22.5 mGy to organs and tissues in the head and neck region when the complete maxilla or mandible was examined. When examining a single tooth gap, only 8% to 40% of that radiation dose was generally observed. Based on these results, the mortality risk was estimated according to a calculation model recommended by the Committee on the Biological Effects of Ionizing Radiations. The mortality risk ranged from 31.4 x 10(-6) for 20-year-old men to 4.8 x 10(-6) for 65-year-old women when cross-sectional imaging of the complete maxilla was performed. The values decreased by 70% when a single tooth gap in the molar region of the maxilla was radiographed. The figures for the mortality risk for examinations of the complete mandible were similar to those for the complete maxilla, but the mortality risk decreased by 80% if only a single tooth gap in the molar region of the mandible was examined. Calculations according to the International Commission on Radiological Protection carried out for comparison did not reveal the decrease of the mortality risk with age and resulted in a higher risk value in comparison to the group of 35-year old individuals in calculations according to the Committee on the Biological Effects of Ionizing Radiations.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9151064     DOI: 10.1111/j.1600-0722.1997.tb00190.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  3 in total

1.  Cone-beam computed tomography evaluation of the pterygomaxillary fissure and pterygopalatine fossa using 3D rendering programs.

Authors:  Murat Icen; Kaan Orhan
Journal:  Surg Radiol Anat       Date:  2019-02-06       Impact factor: 1.246

Review 2.  Correlation between gray values of cone-beam computed tomograms and Hounsfield units of computed tomograms: A systematic review and meta-analysis.

Authors:  Abirami Selvaraj; Ravindra Kumar Jain; Ravleen Nagi; Arthi Balasubramaniam
Journal:  Imaging Sci Dent       Date:  2022-05-13

3.  Effect of patient anxiety on image motion artefacts in CBCT.

Authors:  Elif Yıldızer Keriş
Journal:  BMC Oral Health       Date:  2017-04-04       Impact factor: 2.757

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.