In vitro laxity-testers for knee joints of mice.

L Blankevoort1, G J van Osch, B Janssen, E E Hekman.   

Abstract

The knee joints of mice can be used as a model for studying the effects of interventions on knee laxity. The goal of this study was to quantify knee joint laxity in vitro. Three devices were developed: a positioning- and cementing device, an anterior-posterior (AP) laxity tester and a varus-valgus (VV) laxity tester. The positioning and cementing device was used to position the joint in a reproducible way and to attach clamping pins to the proximal femur and distal tibia using PM MA. The clamping pins were used to fix the joint to the AP- and VV-testers. In both testers the load was applied by means of a spindle-actuated spring while load and displacements were measured simultaneously. The load--displacement data were used to calculate displacement and compliance parameters. The performance of the testers was evaluated by testing 5 normal knee joints of 5 mice. Total AP-translation at + or - 0.8 N was 0.43 (+ or - 0.16 S.D.) mm with compliances of 0.14 (+ or - 0.05 S.D.) mm N(1) and 0.12 ( + or - 10.05 S.D.) mm N(-1) at 0.8 N posterior and anterior force, respectively. Total VV-rotation at + or - 4 Nmm was 17.2 (+ or - 2.6 S.D.) degrees with compliances of 0.9 degrees Nmm(-1) (+ or - 0.2 degrees Nmm(-1) S.D.) and 1.0 Nmm(-1) (+ or - 0.4 degrees Nmm(-1) S.D.) at 4 Nmm valgus and varus moment, respectively. The contributions of the deformations of the bones and the fixtures to the rotations were negligible in the VV-test. In the AP-test they account for approximately 0.07 ( + or - 0.03 S.D.)mm of the total AP-translation. This will not affect the utilization of the device for comparative analysis. It is concluded that in in vitro evaluation of AP- and VV-laxity in knees of mice is feasible with sufficient accuracy for evaluation of changes after ligament damage.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9147978     DOI: 10.1016/0021-9290(95)00130-1

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Comparison of loading rate-dependent injury modes in a murine model of post-traumatic osteoarthritis.

Authors:  Kevin A Lockwood; Bryce T Chu; Matthew J Anderson; Dominik R Haudenschild; Blaine A Christiansen
Journal:  J Orthop Res       Date:  2013-09-09       Impact factor: 3.494

2.  Osteophyte formation after ACL rupture in mice is associated with joint restabilization and loss of range of motion.

Authors:  Allison W Hsia; Matthew J Anderson; Mollie A Heffner; Earl P Lagmay; Regina Zavodovskaya; Blaine A Christiansen
Journal:  J Orthop Res       Date:  2016-04-13       Impact factor: 3.494

3.  Novel model for the induction of postnatal murine hip deformity.

Authors:  Megan L Killian; Ryan C Locke; Michael G James; Penny R Atkins; Andrew E Anderson; John C Clohisy
Journal:  J Orthop Res       Date:  2018-11-19       Impact factor: 3.494

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.