Literature DB >> 9147911

Analytic performance and contamination control methods of a ligase chain reaction DNA amplification assay for detection of Chlamydia trachomatis in urogenital specimens.

H Y Hu1, J D Burczak, G W Leckie, K A Ray, S Muldoon, H H Lee.   

Abstract

A ligase chain reaction (LCR) DNA amplification assay that targeted the cryptic plasmid of Chlamydia trachomatis was developed to detect C. trachomatis urogenital tract infection. The objectives of this study were to determine the cutoff and analytic performance of the LCR assay and to characterize the effectiveness of its postdetection contamination control method. The assay's cutoff was determined after receiver-operator characteristic (ROC) analysis of 4660 clinical data points. The assay detected one infectious unit per reaction of each of the 15 C. trachomatis serovars and did not cross-react with 13 Chlamydia pneumoniae strains, 13 Chlamydia psittaci strains, and 87 other bacteria, fungi, parasites, or viruses. In addition, the assay did not detect 77 processed urine specimens collected from patients with urinary tract infections caused by yeast or bacteria other than C. trachomatis. The assay was sufficiently precise to detect consistently two infectious units of C. trachomatis per reaction. False-positive assay results attributable to contamination with amplified product were minimized by the use of standard procedures as well as by a postdetection chemical inactivation method that could reduce the amount of amplified LCR product by a factor of > or = 10(7).

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9147911     DOI: 10.1016/0732-8893(95)00272-3

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  4 in total

1.  Performance of a multiplex qualitative PCR LCx assay for detection of human immunodeficiency virus type 1 (HIV-1) group M subtypes, group O, and HIV-2.

Authors:  K Abravaya; C Esping; R Hoenle; J Gorzowski; R Perry; P Kroeger; J Robinson; R Flanders
Journal:  J Clin Microbiol       Date:  2000-02       Impact factor: 5.948

2.  Effect of urine specimen dilution on the performance of two commercial systems in the detection of Chlamydia trachomatis infection in men.

Authors:  R Pasternack; P Vuorinen; A Miettinen
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1998-09       Impact factor: 3.267

3.  Method for reduction of inhibition in a Mycobacterium tuberculosis-specific ligase chain reaction DNA amplification assay.

Authors:  G W Leckie; D D Erickson; Q He; I E Facey; B C Lin; J Cao; F G Halaka
Journal:  J Clin Microbiol       Date:  1998-03       Impact factor: 5.948

4.  Direct detection of Mycobacterium tuberculosis complex in clinical samples from patients in Norway by ligase chain reaction.

Authors:  A Lindbråthen; P Gaustad; B Hovig; T Tønjum
Journal:  J Clin Microbiol       Date:  1997-12       Impact factor: 5.948

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.