Literature DB >> 9146515

Stability after surgical correction of mandibular prognathism using the sagittal split ramus osteotomy and fixation with poly-L-lactic acid (PLLA) screws.

K Harada1, S Enomoto.   

Abstract

PURPOSE: This study was designed to examine skeletal stability after surgical correction of mandibular prognathism using a sagittal split ramus osteotomy (SSRO) and fixation with poly-L-lactic acid (PLLA) screws. PATIENTS AND METHODS: Twenty patients with Class III malocclusion were treated with bilateral SSRO and mandibular setback. Ten underwent fixation with titanium screws (group I) and the other 10 with PLLA screws (group II). Cephalograms were obtained 2 or 3 days postoperatively, and at 3, 6, and 12 months after the operation. Changes in the position of upper incisors (U-1), lower incisors (L-1), B-point, and pogonion were examined on lateral cephalograms.
RESULTS: Certain tendencies for overjet and overbite were noted to have decreased more markedly, and changes in the position of the skeletal points were greater in group II than in group I. However, statistical analysis showed no significant differences between the two groups.
CONCLUSION: Our results suggest that fixation of the bony segments with PLLA screws after SSRO may be used effectively in properly selected cases.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9146515     DOI: 10.1016/s0278-2391(97)90691-1

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  5 in total

1.  Biodegradable fixation for craniomaxillofacial surgery: a 10-year experience involving 761 operations and 745 patients.

Authors:  T A Turvey; W P Proffit; C Phillips
Journal:  Int J Oral Maxillofac Surg       Date:  2010-12-24       Impact factor: 2.789

2.  Enhanced endothelialization on surface modified poly(L-lactic acid) substrates.

Authors:  Hao Xu; Rajendrasing Deshmukh; Richard Timmons; Kytai Truong Nguyen
Journal:  Tissue Eng Part A       Date:  2010-12-18       Impact factor: 3.845

3.  Efficacy of bioresorbable plates in the osteosynthesis of linear mandibular fractures.

Authors:  Satyavrat Arya; Krushna Bhatt; Ongkila Bhutia; Ajoy Roychoudhury
Journal:  Natl J Maxillofac Surg       Date:  2020-06-18

4.  Is There Any Differences in Dento-Skeletal Stability between One Vs. Three-Screw Fixation of Mandible Following Bilateral Sagittal Split Osteotomy (BSSO)?

Authors:  Majid Eshghpour; Sahand Samieirad; Farzaneh MohammadZadeh Mahrokh; Niloofar EbrahimZadeh; Samine Mozaffar; Haleh Hashemzadeh
Journal:  World J Plast Surg       Date:  2022-07

Review 5.  Efficacy and morbidity of biodegradable versus titanium osteosyntheses in orthognathic surgery: A systematic review with meta-analysis and trial sequential analysis.

Authors:  Barzi Gareb; Nico B van Bakelen; Pieter U Dijkstra; Arjan Vissink; Ruud R M Bos; Baucke van Minnen
Journal:  Eur J Oral Sci       Date:  2021-06-15       Impact factor: 2.612

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.