Literature DB >> 9143066

Evaluation and characterization of carotid plaque.

E I Bluth1.   

Abstract

Doppler sonography, combining high-resolution imaging and Doppler spectrum analysis, has proven to be the best choice for safe, noninvasive, low-cost screening for the etiology of stroke. With high-resolution imaging, plaque can be characterized relative to the risk for intraplaque hemorrhage, thought by many to be the precursor of plaque ulceration. Using high-resolution ultrasound, heterogeneous plaque has been shown to be associated with intraplaque hemorrhage. Criteria for distinguishing heterogeneous from homogeneous plaque are discussed, as are techniques for characterizing plaque. Several published articles strongly suggest that, when heterogeneous plaques are identified, the incidence of neurological symptoms and stroke on follow-up increases, relative to patients with homogeneous plaques. Additional long-term follow-up studies of heterogeneous plaque are needed. Most recently, carotid wall thickness has been evaluated as a physiological marker for atherosclerotic disease and as a gauge of the effectiveness of medical therapies. It is likely that carotid wall thickness will become important in the diagnosis and management of atherosclerosis. Radiologist are encouraged to learn this new form of ultrasound examination, which is reviewed briefly in this article.

Entities:  

Mesh:

Year:  1997        PMID: 9143066     DOI: 10.1016/s0887-2171(97)90038-x

Source DB:  PubMed          Journal:  Semin Ultrasound CT MR        ISSN: 0887-2171            Impact factor:   1.875


  4 in total

1.  Preoperative extracranial carotid artery examination with ultrasonography in patients undergoing coronary artery bypass grafting in Japan.

Authors:  Syouichi Arai; Hidetsuna Utsunomiya; Tadashi Tashiro; Kiyokazu Ishida; Masatoshi Okazaki
Journal:  Radiat Med       Date:  2006-04

Review 2.  Indications for carotid artery surgery and stent: the role of carotid ultrasound.

Authors:  Yong Jae Kim; Charles H Tegeler
Journal:  Curr Cardiol Rep       Date:  2008-02       Impact factor: 2.931

3.  Relationship between ultrasonic attenuation, size and axial strain parameters for ex vivo atherosclerotic carotid plaque.

Authors:  Hairong Shi; Tomy Varghese; Robert J Dempsey; Mohammed S Salamat; James A Zagzebski
Journal:  Ultrasound Med Biol       Date:  2008-05-19       Impact factor: 2.998

4.  Evaluation of carotid arteries in stroke patients using color Doppler sonography: A prospective study conducted in a tertiary care hospital in South India.

Authors:  Merwyn Fernandes; B Keerthiraj; Ajith R Mahale; Ashwini Kumar; Anees Dudekula
Journal:  Int J Appl Basic Med Res       Date:  2016 Jan-Mar
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.