Literature DB >> 9143061

Clinical experience with sonographic contrast agents.

M L Melany1, E G Grant.   

Abstract

Early generations of sonographic contrast agents are beginning to reach the attention of the clinician. Research and development of ultrasound contrast agents is progressing at a rapid pace with several new agents approaching US Food and Drug Administration approval. Cardiac imaging has been affected by even the limited availability of contrast agents on the market today both with regard to diagnosis of shunts and chamber opacification, and most recently actual enhancement of the myocardium. Later generations of contrast are capable of providing consistent opacification of both peripheral veins and arteries, and should prove useful in a variety clinical applications. Thus far, it appears that longer vessel segments may be seen with contrast rather than without contrast, and that flow may be demonstrated in vessels which were not seen or thought to be occluded with conventional color imaging. Improved detection of arterial and venous collaterals and enhanced identification of run-off vessels is demonstrated with sonographic contrast agents. An improved ability to evaluate renal artery stenosis and subtotal occlusion of the carotid artery are specific advantages of using contrast as well. Several compounds are currently being tested that may allow routine parenchymal opacification. Ultrasound is the most commonly performed diagnostic imaging procedure; therefore, contrast agents have the potential to dramatically alter the practice of clinical medicine. This article reviews the current status of ultrasound contrast agents and speculates regarding the future applications of these agents.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9143061     DOI: 10.1016/s0887-2171(97)90033-0

Source DB:  PubMed          Journal:  Semin Ultrasound CT MR        ISSN: 0887-2171            Impact factor:   1.875


  3 in total

1.  Differential diagnosis between gallbladder adenomas and cholesterol polyps on contrast-enhanced harmonic endoscopic ultrasonography.

Authors:  Chan Hyuk Park; Moon Jae Chung; Tak Geun Oh; Jeong Youp Park; Seungmin Bang; Seung Woo Park; Hyunki Kim; Ho Kyoung Hwang; Woo Jung Lee; Si Young Song
Journal:  Surg Endosc       Date:  2012-12-12       Impact factor: 4.584

2.  The use of contrast-enhanced color Doppler ultrasound in the differentiation of retinal detachment from vitreous membrane.

Authors:  S S Han; S K Chang; J H Yoon; Y J Lee
Journal:  Korean J Radiol       Date:  2001 Oct-Dec       Impact factor: 3.500

Review 3.  Perflenapent emulsion (EchoGen): a new long-acting phase-shift agent for contrast echocardiography.

Authors:  P Grayburn
Journal:  Clin Cardiol       Date:  1997-10       Impact factor: 2.882

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.