Literature DB >> 9142590

Lower respiratory rates without decreases in oxygen consumption during neonatal synchronized intermittent mandatory ventilation.

K M Smith1, T M Wahlig, D R Bing, M K Georgieff, S J Boros, M C Mammel.   

Abstract

OBJECTIVE: We tested the hypothesis that synchronization to patient effort during intermittent mandatory ventilation (SIMV), when compared to conventional unsynchronized intermittent mandatory ventilation (IMV), will decrease energy expenditure, as reflected by decreased oxygen consumption (VO2).
DESIGN: We used a four-period crossover design. Each patient was studied over four 30-min continuous time intervals. Patients were randomized to receive initially IMV or SIMV, then crossed over such that each patient was treated twice with each modality. Data were analyzed using an analysis of variance technique.
SETTING: Patients were receiving treatment in the newborn intensive care unit of Children's Hospital, St. Paul. PATIENTS: We studied 17 patients, who ranged from 23 to 37 weeks gestation, were < or = 14 days old, and had study weights from 623 to 3015 g. All were mechanically ventilated for hyaline membrane disease. MEASUREMENTS AND
RESULTS: We measured and compared VO2, carbon dioxide consumption (VCO2), minute ventilation (VE), total respiratory rate, heart rate, arterial blood pressure, and arterial oxygen saturation (SaO2) values during IMV and SIMV. Total respiratory rate fell significantly during SIMV (73 +/- 26 during IMV, 57 +/- 17 during SIMV, p < 0.01) in spite of no significant change in VO2 (0.6 +/- 0.16% fall in VO2 during SIMV) or VCO2 (4.2 +/- 0.19% increase in VCO2 during SIMV) values. Moreover, there were no significant differences in heart rate, blood pressure, VE, or SaO2 values with either form of therapy.
CONCLUSIONS: Though total respiratory rate fell, these data do not support the hypothesis that SIMV significantly reduces respiratory rate by decreasing oxygen consumption and carbon dioxide production during infant mechanical ventilation. Rather, the marked fall in respiratory rate may be due to a more efficient respiratory pattern.

Entities:  

Mesh:

Year:  1997        PMID: 9142590     DOI: 10.1007/s001340050359

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  1 in total

Review 1.  Synchronized mechanical ventilation for respiratory support in newborn infants.

Authors:  Anne Greenough; Thomas E Rossor; Adesh Sundaresan; Vadivelam Murthy; Anthony D Milner
Journal:  Cochrane Database Syst Rev       Date:  2016-09-01