Literature DB >> 9142037

Significant reduction in minute ventilation and peak inspiratory pressures with arteriovenous CO2 removal during severe respiratory failure.

W Tao1, R L Brunston, A Bidani, P Pirtle, J Dy, V J Cardenas, D L Traber, J B Zwischenberger.   

Abstract

OBJECTIVES: To quantify CO2 removal using an extracorporeal low-resistance membrane gas exchanger placed in an arteriovenous shunt and evaluate its effects on the reduction of ventilatory volumes and airway pressures during severe respiratory failure induced by smoke inhalation injury.
DESIGN: Prospective study.
SETTING: Research laboratory.
SUBJECTS: Adult female sheep (n = 5).
INTERVENTIONS: Animals were instrumented with femoral and pulmonary arterial catheters and underwent an LD50 cotton smoke inhalation injury via a tracheostomy under halothane anesthesia. Twenty-four hours after smoke inhalation injury, the animals were reanesthetized and systemically heparinized for cannulation of the left carotid and common jugular vein to construct a simple arteriovenous shunt. A membrane gas exchanger was interposed within the arteriovenous shunt, and blood flow produced by the arteriovenous pressure gradient was unrestricted at the time of complete recovery from anesthesia. CO2 removal by the gas exchanger was measured as the product of the sweep gas flow (FIO2 of 1.0 at 2.5 to 3.0 L/min) and the exhaust CO2 content measured with an inline capnometer. CO2 removed by the animal's lungs was determined by the expired gas CO2 content in a Douglas bag. We made stepwise, 20% reductions in ventilator support hourly. We first reduced the tidal volume to achieve a peak inspiratory pressure of < 30 cm H2O, and then we reduced the respiratory rate while maintaining normocapnia. PaO2 was maintained by adjusting the FIO2 and the level of positive end-expiratory pressure.
MEASUREMENTS AND MAIN RESULTS: Mean blood flow through the arteriovenous shunt ranged from 1154 +/- 82 mL/min (25% cardiac output) to 1277 +/- 38 mL/min (29% cardiac output) over the 6-hr study period. The pressure gradient across the gas exchanger was always < 10 mm Hg. Maximum arteriovenous CO2 removal was 102.0 +/- 9.5 mL/min (96% of total CO2 production), allowing minute ventilation to be reduced from 10.3 +/- 1.4 L/min (baseline) to 0.5 +/- 0.0 L/min at 6 hrs of arteriovenous CO2 removal while maintaining normocapnia. Similarly, peak inspiratory pressure decreased from 40.8 +/- 2.1 to 19.7 +/- 7.5 cm H2O. PaO2 was maintained at > 100 torr (> 13.3 kPa) at maximally reduced ventilator support. Mean arterial pressure and cardiac output did not change significantly as a result of arteriovenous shunting.
CONCLUSIONS: Extracorporeal CO2 removal using a low-resistance gas exchanger in a simple arteriovenous shunt allows significant reduction in minute ventilation and peak inspiratory pressure without hypercapnia or the complex circuitry and monitoring required for conventional extracorporeal membrane oxygenation. Arteriovenous CO2 removal can be applied as an easy and cost-effective treatment to minimize ventilator-induced barotrauma and volutrauma during severe respiratory failure.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9142037     DOI: 10.1097/00003246-199704000-00022

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  6 in total

1.  Reduced ventilator pressure and improved P/F ratio during percutaneous arteriovenous carbon dioxide removal for severe respiratory failure.

Authors:  S K Alpard; J B Zwischenberger; W Tao; D J Deyo; A Bidani
Journal:  Ann Surg       Date:  1999-08       Impact factor: 12.969

Review 2.  An update on interventional lung assist devices and their role in acute respiratory distress syndrome.

Authors:  Marc-Alexander von Mach; Joachim Kaes; Babatunde Omogbehin; Ingo Sagoschen; Jascha Wiechelt; Kristina Kaiser; Oliver Sauer; Ludwig Sacha Weilemann
Journal:  Lung       Date:  2006 May-Jun       Impact factor: 2.584

3.  Oxygenation effect of interventional lung assist in a lavage model of acute lung injury: a prospective experimental study.

Authors:  Günther Zick; Inéz Frerichs; Dirk Schädler; Gunnar Schmitz; Sven Pulletz; Erol Cavus; Felix Wachtler; Jens Scholz; Norbert Weiler
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

4.  Cardiovascular stability during arteriovenous extracorporeal therapy: a randomized controlled study in lambs with acute lung injury.

Authors:  Balagangadhar R Totapally; Jeffrey B Sussmane; Dan Torbati; Javier Gelvez; Harun Fakioglu; Yongming Mao; Jose L Olarte; Jack Wolfsdorf
Journal:  Crit Care       Date:  2004-10-28       Impact factor: 9.097

5.  Thrombotic Complications during Interventional Lung Assist: Case Series.

Authors:  Eun Jung Kim; Woo Hyun Cho; Eun Young Ahn; Dae Gon Ryu; Seung Eun Lee; Doo Soo Jeon; Yun Seong Kim; Bong Soo Son; Do Hyung Kim
Journal:  Tuberc Respir Dis (Seoul)       Date:  2015-01-29

6.  Arteriovenous Extracorporeal Lung Assist Allows For Maximization Of Oscillatory Frequencies: A Large-animal Model Of Respiratory Distress.

Authors:  Ralf M Muellenbach; Julian Kuestermann; Markus Kredel; Amélie Johannes; Ulrike Wolfsteiner; Frank Schuster; Christian Wunder; Peter Kranke; Norbert Roewer; Jörg Brederlau
Journal:  BMC Anesthesiol       Date:  2008-11-14       Impact factor: 2.217

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.