Literature DB >> 9141121

The effects of prosthesis mass on metabolic cost of ambulation in non-vascular trans-tibial amputees.

R S Gailey1, M S Nash, T A Atchley, R M Zilmer, G R Moline-Little, N Morris-Cresswell, L I Siebert.   

Abstract

The effect of prosthesis mass on the metabolic cost of steady-state walking was studied in ten male non-vascular trans-tibial amputees (TTAs) and ten non-amputee controls. The subjects underwent four trials of treadmill ambulation, with each trial performed for nine minutes at level grade and 76 m/min. Twenty minutes of seated rest followed each trial. During trials numbers one and two, TTAs ambulated without mass added to their prosthesis. During the third and fourth trials, either 454 or 907 grammes mass (1 or 2lbs mass respectively) were randomly assigned and added to either the prosthesis or the leg of the non-amputee control. Subjects were blinded to the amount of mass added to their limb. Within-group comparisons across the four trials showed significant differences in oxygen consumption (VO2) and heart rate (HR) between the two non "mass added" trials, but no effect for addition of mass. The VO2 of TTAs was only 0.6 ml/kg/min (4.7 percent) greater during walking following the addition of 907 grammes to the prosthesis than without mass addition at all, while HR averaged only 1.4 beats/min. higher under the same testing condition. Pearson-product moment correlations echoed these findings, as moderate, but in all cases, negative correlations were observed for associations among the factors of subject age, stump length, and prosthesis-shoe weight, and both VO2 and HR. It was concluded that adding up to 907 grammes mass to a non-vascular TTA's prosthesis will not significantly increase the energy expenditure or HR at a normal walking speed, and that elevated energy cost of ambulation in repeated measures testing without mass added may reflect task familiarization and not an added burden of prosthesis mass.

Entities:  

Mesh:

Year:  1997        PMID: 9141121     DOI: 10.3109/03093649709164525

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  7 in total

Review 1.  Heat-related issues and practical applications for Paralympic athletes at Tokyo 2020.

Authors:  Katy E Griggs; Ben T Stephenson; Michael J Price; Victoria L Goosey-Tolfrey
Journal:  Temperature (Austin)       Date:  2019-06-27

2.  Design of an Underactuated Powered Ankle and Toe Prosthesis.

Authors:  Lukas Gabert; Minh Tran; Tommaso Lenzi
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2021-11

Review 3.  Considerations for development of sensing and monitoring tools to facilitate treatment and care of persons with lower-limb loss: a review.

Authors:  Brian J Hafner; Joan E Sanders
Journal:  J Rehabil Res Dev       Date:  2014

4.  Energetic consequences of using a prosthesis with adaptive ankle motion during slope walking in persons with a transtibial amputation.

Authors:  Benjamin J Darter; Jason M Wilken
Journal:  Prosthet Orthot Int       Date:  2013-03-22       Impact factor: 1.895

5.  Knee extensor power predicts six-minute walk test performance in people with transfemoral amputations.

Authors:  Lindsay Slater; Suzanne Finucane; Levi J Hargrove
Journal:  PM R       Date:  2021-06-09       Impact factor: 2.218

6.  Shortcomings of human-in-the-loop optimization of an ankle-foot prosthesis emulator: a case series.

Authors:  Cara Gonzalez Welker; Alexandra S Voloshina; Vincent L Chiu; Steven H Collins
Journal:  R Soc Open Sci       Date:  2021-05-05       Impact factor: 2.963

7.  Effect of toe joint stiffness and toe shape on walking biomechanics.

Authors:  Eric C Honert; Gerasimos Bastas; Karl E Zelik
Journal:  Bioinspir Biomim       Date:  2018-10-10       Impact factor: 2.956

  7 in total