Literature DB >> 9139101

Prospective study of 100 consecutive Harris-Galante porous total hip arthroplasties. 4- to 8-year follow-up study.

W J Petersilge1, D D D'Lima, R H Walker, C W Colwell.   

Abstract

This prospective study evaluates 100 consecutive Harris-Galante Porous (Zimmer, Warsaw, IN) noncemented femoral prostheses 4 to 8 years after surgery. Two femoral components were revised for aseptic loosening. The mean Harris hip score was 56 before surgery and 92 at final follow-up evaluation, with moderate thigh pain seen in 6%. Ingrowth was classified as bony (89%), stable fibrous (8%), and unstable (3%). A pedestal formed in 18%, measurable subsidence occurred in 22%, and endosteal erosion occurred in 12%. Patients with pedestal formation had a higher incidence of unstable growth pattern (P < .05). Patients with bony ingrowth had a lower mean subsidence (0.38 mm) than those with fibrous stable ingrowth (3 mm) and unstable ingrowth (7.5 mm) (P < .05). Thigh pain correlated with the type of ingrowth, and endosteal erosion with the linear polyethylene wear. Survival analysis was 97.5% at 8 years.

Entities:  

Mesh:

Year:  1997        PMID: 9139101     DOI: 10.1016/s0883-5403(97)90065-6

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

1.  An in vivo evaluation of bone response to three implant surfaces using a rabbit intramedullary rod model.

Authors:  Juan C Hermida; Arnie Bergula; Fred Dimaano; Monica Hawkins; Clifford W Colwell; Darryl D D'Lima
Journal:  J Orthop Surg Res       Date:  2010-08-16       Impact factor: 2.359

2.  Frictional and bone ingrowth properties of engineered surface topographies produced by electron beam technology.

Authors:  J Elizabeth Biemond; René Aquarius; Nico Verdonschot; Pieter Buma
Journal:  Arch Orthop Trauma Surg       Date:  2010-12-16       Impact factor: 3.067

3.  The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups--finite element simulations and experimental tests.

Authors:  Rami K Korhonen; Arto Koistinen; Yrjö T Konttinen; Seppo S Santavirta; Reijo Lappalainen
Journal:  Biomed Eng Online       Date:  2005-05-17       Impact factor: 2.819

4.  Comparison of modular and nonmodular tapered fluted titanium stems in femoral revision hip arthroplasty: a minimum 6-year follow-up study.

Authors:  Shuo Feng; Yu Zhang; Yu-Hang Bao; Zhi Yang; Guo-Chun Zha; Xiang-Yang Chen
Journal:  Sci Rep       Date:  2020-08-13       Impact factor: 4.379

  4 in total