Literature DB >> 9139097

Patellar component medialization in total knee arthroplasty.

A A Hofmann1, T K Tkach, C J Evanich, M P Camargo, Y Zhang.   

Abstract

Intraoperative correction of patellar maltracking has traditionally involved the use of a lateral retinacular release. Problems, however, related to lateral retinacular release include increased postoperative pain and wound healing complications, compromised patellar blood flow, and longer rehabilitation. The purpose of this study was to assess the effect of patellar medialization in total knee arthroplasty. One hundred forty patients underwent total knee arthroplasty using the same components. Two groups of 70 patients each made up the study. Group 1 included patients whose patellar components were centralized on the patella, and group 2 consisted of patients in whom the patellar component was medialized to reproduce the patient's anatomic high point (ie, sagittal ridge). Lateral retinacular release was required in 45.5% of the patients in group 1 compared with 17% in group 2. The technique of patellar medialization is described.

Entities:  

Mesh:

Year:  1997        PMID: 9139097     DOI: 10.1016/s0883-5403(97)90061-9

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  11 in total

1.  Native femoral sulcus as a guide for the position of the femoral component in primary total knee arthroplasty: a prospective comparative study of 420 knees.

Authors:  Fang-Yao Chiu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-08-26       Impact factor: 4.342

2.  Optimizing patellar positioning during total knee arthroplasty: an anatomical and clinical study.

Authors:  Chahine Assi; Nadim Kheir; Camille Samaha; Mary Deeb; Kaissar Yammine
Journal:  Int Orthop       Date:  2017-07-15       Impact factor: 3.075

3.  The geometry of patella and patellar tendon measured on knee MRI.

Authors:  Jae Ho Yoo; Seung Rim Yi; Jin Hong Kim
Journal:  Surg Radiol Anat       Date:  2007-09-26       Impact factor: 1.246

Review 4.  Patellar malalignment treatment in total knee arthroplasty.

Authors:  Giorgio Gasparini; Filippo Familiari; Francesco Ranuccio
Journal:  Joints       Date:  2013-06-12

5.  [Digital study on the relationship between position of patellar high point and shape of osteotomy surface in Chinese].

Authors:  Changzhao Li; Peiheng He; Yong Liu; Dongliang Xu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-07-15

Review 6.  Management of patella maltracking after total knee arthroplasty: a systematic review.

Authors:  R Ferri; V Digennaro; A Panciera; B D Bulzacki Bogucki; D Cecchin; M Manzetti; M Brunello; C Faldini
Journal:  Musculoskelet Surg       Date:  2022-10-05

7.  Safety and Efficacy of 6.2 mm Patellar Button in Resurfacing Less than 20 mm Thin Patella: A Matched Pair Analysis.

Authors:  Anoop Jhurani; Piyush Agarwal; Mukesh Aswal; Purvi Saxena; Nidhi Singh
Journal:  Knee Surg Relat Res       Date:  2018-06-01

8.  Musculoskeletal Multibody Simulation Analysis on the Impact of Patellar Component Design and Positioning on Joint Dynamics after Unconstrained Total Knee Arthroplasty.

Authors:  Maeruan Kebbach; Martin Darowski; Sven Krueger; Christoph Schilling; Thomas M Grupp; Rainer Bader; Andreas Geier
Journal:  Materials (Basel)       Date:  2020-05-21       Impact factor: 3.623

9.  Comparison of Patellofemoral-Specific Clinical and Radiographic Results after Total Knee Arthroplasty Using a Patellofemoral Design-Modified Prosthesis and Its Predecessor.

Authors:  Sang Jun Song; Kang Il Kim; Dong Uk Suh; Cheol Hee Park
Journal:  Clin Orthop Surg       Date:  2021-02-02

10.  Intraoperative Patella Dimension Measurement in Asian Female Patients and Its Relevance in Patellar Resurfacing in TKA.

Authors:  Shaifuzain Ab Rahman; Amran Ahmed Shokri; Muhammad Rajaie Ahmad; Ahmad Filza Ismail; Nur Syahida Termizi
Journal:  Adv Orthop       Date:  2020-04-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.