Omental herniation through a 5-mm laparoscopic cannula site.

D B Toub1, M J Campion.   

Abstract

Herniation is a rare complication of laparoscopy, and has not previously been reported to occur through a 5-mm puncture site. A patient experienced an incarcerated omental prolapse through an incision for a 5-mm cannula 4 days after undergoing a laparoscopic radical hysterectomy. Based on our experience, we recommend fascial closure of all laparoscopic cannula insertion sites if possible, and emphasize the need for evaluating omental or enteric protrusions through even small fascial defects.

Entities:  

Mesh:

Year:  1994        PMID: 9138885     DOI: 10.1016/s1074-3804(05)80809-6

Source DB:  PubMed          Journal:  J Am Assoc Gynecol Laparosc        ISSN: 1074-3804


  3 in total

Review 1.  Laparoscopic 5-mm trocar site herniation and literature review.

Authors:  Miya Yamamoto; Laura Minikel; Eve Zaritsky
Journal:  JSLS       Date:  2011 Jan-Mar       Impact factor: 2.172

2.  Severe bowel incarceration in an eight-millimeter left-lateral trocar site after robot-assisted laparoscopic colposacropexy: A case report.

Authors:  Elisabetta Micelli; Eleonora Russo; Paolo Mannella; Veronica Iodice; Giulia Cappellini; Nadia Falchi; Federica Pancetti; Tommaso Simoncini; Andrea Giannini
Journal:  Case Rep Womens Health       Date:  2019-10-14

Review 3.  5-millimeter trocar-site bowel herniation following laparoscopic surgery.

Authors:  Nauman Khurshid; Maurice Chung; Terrence Horrigan; Kelly Manahan; John P Geisler
Journal:  JSLS       Date:  2012 Apr-Jun       Impact factor: 2.172