Literature DB >> 9136185

Direct measurement of clamping forces in cardiovascular surgery.

R Trobec1, B Gersak.   

Abstract

Equipment for measuring the direct tip force of a clamp arm on the vessel wall is designed as an adjustable surgical clamp with strain gauges applied and connected via an amplifier to a computer-based data acquisition system. A mechanical model that incorporates the resistance of tissue against momentary deformations is developed to analyse and justify measured results. In in vivo experiments on rat thoracic aorta, the minimum occlusion force, stationary clamping force and the momentary peak clamping force are measured and observed as an important cause of damages in the endothelial layer of vascular walls.

Entities:  

Mesh:

Year:  1997        PMID: 9136185     DOI: 10.1007/bf02510386

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  A scanning electron microscopy study of micro-arterial damage and repair.

Authors:  J B Thurston; H J Buncke; N L Chater; P R Weinstein
Journal:  Plast Reconstr Surg       Date:  1976-02       Impact factor: 4.730

2.  Comparison between absorbable and nonabsorbable sutures in arterial anastomoses in growing dogs.

Authors:  B Gersak
Journal:  J Cardiovasc Surg (Torino)       Date:  1991 Nov-Dec       Impact factor: 1.888

3.  Fibrous changes and presence of calcium in the vessel walls six months after end-to-end arterial anastomoses in growing dogs.

Authors:  B Gersak
Journal:  J Thorac Cardiovasc Surg       Date:  1990-02       Impact factor: 5.209

4.  Fasciculations in motor neuron disease: discharge rate reflects extent and recency of collateral sprouting.

Authors:  M Janko; J V Trontelj; K Gersak
Journal:  J Neurol Neurosurg Psychiatry       Date:  1989-12       Impact factor: 10.154

5.  Effect of vascular clamp on endothelial integrity of the internal mammary artery.

Authors:  J Kuo; K Ramstead; V Salih; A Coumbe; T R Graham; C T Lewis
Journal:  Ann Thorac Surg       Date:  1993-04       Impact factor: 4.330

6.  Scanning electron microscope study of experimental microvascular anastomoses in the rabbit.

Authors:  G Nightingale; I Fogdestam; B M O'Brien
Journal:  Br J Plast Surg       Date:  1980-04

7.  Minimum vascular occlusive force.

Authors:  M Dujovny; N Wakenhut; N Kossovsky; C W Gomes; R K Laha; L Leff; D Nelson
Journal:  J Neurosurg       Date:  1979-11       Impact factor: 5.115

8.  Aneurysms after microvascular anastomoses. Incidence and pathogenesis in experimental animals.

Authors:  G P Maxwell; Z Szabo; H J Buncke
Journal:  Plast Reconstr Surg       Date:  1979-06       Impact factor: 4.730

9.  Presence of calcium in the vessel walls after end-to-end arterial anastomoses with polydioxanone and polypropylene sutures in growing dogs.

Authors:  B Gersak
Journal:  J Thorac Cardiovasc Surg       Date:  1993-10       Impact factor: 5.209