Characterization of the response of commercial diode detectors used for in vivo dosimetry.

R J Meiler1, M B Podgorsak.   

Abstract

The response of a commercially available diode-based in vivo dosimetry system was studied over a selection of clinically relevant photon beam setups. The dosimetry system consists of a dedicated multichannel electrometer with several diode detectors differing only in their equivalent wall buildup. Each detector is calibrated for a specific nominal beam energy and used clinically with that energy only. To study dosimeter response, a diode taped to the surface of a solid water phantom was irradiated simultaneously with an end-window chamber placed at a depth of dmax inside the same phantom. Photon beams with energies of Co-60, 6 and 18 MV were used. For each beam energy, the response of the diode relative to the given dose as measured by the end-window chamber was evaluated for open and wedged fields (0 degree to 60 degrees) with source-to-surface distances (SSDs) ranging from 75 to 120 cm and collimator settings from 5 x 5 to 40 x 40 cm2. It was found that diode response, i.e., diode reading per cGy of given dose, varies significantly with treatment beam setup. For example, increasing field size for a constant SSD causes a decrease of up to 15% in diode response relative to the given dose for 6 and 18 MV beams, while for Co-60 an increase in response of up to 5% results. Furthermore, increasing SSD for a fixed collimator setting results in decreased diode response (up to 10%) for all beams. The complicated dependence of diode response on beam setup necessitates the use of empirical response curves, similar to those evaluated in this work, to accurately convert clinical dosimeter reading to dose at depth.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9136105     DOI: 10.1016/s0958-3947(96)00152-5

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  5 in total

1.  Validation of an in-vivo proton beam range check method in an anthropomorphic pelvic phantom using dose measurements.

Authors:  El H Bentefour; Shikui Tang; Ethan W Cascio; Mauro Testa; Deepak Samuel; Damien Prieels; Bernard Gottschalk; Hsiao-Ming Lu
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

2.  Commissioning compensator-based IMRT on the Pinnacle treatment planning system.

Authors:  Daniel Opp; Kenneth Forster; Vladimir Feygelman
Journal:  J Appl Clin Med Phys       Date:  2011-03-08       Impact factor: 2.102

3.  In vivo dosimetry using a single diode for megavoltage photon beam radiotherapy: implementation and response characterization.

Authors:  V C Colussi; A S Beddar; T J Kinsella; C H Sibata
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

4.  Entrance dose measurements for in-vivo diode dosimetry: Comparison of correction factors for two types of commercial silicon diode detectors.

Authors:  X R Zhu
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

5.  Characterization of MOSkin detector for in vivo skin dose measurement during megavoltage radiotherapy.

Authors:  Wei Loong Jong; Jeannie Hsiu Ding Wong; Ngie Min Ung; Kwan Hoong Ng; Gwo Fuang Ho; Dean L Cutajar; Anatoly B Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.