A new design of carbon fiber microelectrode for in vivo voltammetry using fused silica.

A H Swiergiel1, V S Palamarchouk, A J Dunn.   

Abstract

Voltammetric probes were constructed from stainless steel and fused silica tubing sheathing carbon fibers. Electrochemical tests were carried out to compare these electrodes with commercially available glass-sealed IVEC-5 electrodes. Electrodes of both types displayed a similar declining baseline and calculated coefficients of stabilization (tangent of baseline during a stable period). There were no significant differences in sensitivity between the two designs of electrodes to norepinephrine (NE) and dopamine (DA). All tested electrodes showed linear current responses to increasing concentrations of NE and DA. Fused silica (FS type) electrodes are suitable for electrochemical measurements (in vivo voltammetry) and display characteristics similar to those of commercially available IVEC-5 glass-sealed carbon fiber microelectrodes. Manufacture of FS type electrodes in a biochemical laboratory is easy and does not require any special equipment (such as a micropipette puller) or glass-handling skills. An additional fused silica tube can be glued to the electrode for microinjections. The electrodes are very robust, easy to handle and can be mounted on the arms of standard stereotaxic instruments. The electrodes can be made long enough to reach the deepest parts of brain of large animals.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9130675     DOI: 10.1016/s0165-0270(96)02207-8

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  5 in total

Review 1.  Electrochemical Analysis of Neurotransmitters.

Authors:  Elizabeth S Bucher; R Mark Wightman
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2015-05-04       Impact factor: 10.745

2.  Phasic dopamine signals: from subjective reward value to formal economic utility.

Authors:  Wolfram Schultz; Regina M Carelli; R Mark Wightman
Journal:  Curr Opin Behav Sci       Date:  2015-10

3.  Simultaneous monitoring of dopamine concentration at spatially different brain locations in vivo.

Authors:  Matthew K Zachek; Pavel Takmakov; Jinwoo Park; R Mark Wightman; Gregory S McCarty
Journal:  Biosens Bioelectron       Date:  2009-10-15       Impact factor: 10.618

4.  Real-time dopamine measurement in awake monkeys.

Authors:  Erik W Schluter; Andrew R Mitz; Joseph F Cheer; Bruno B Averbeck
Journal:  PLoS One       Date:  2014-06-12       Impact factor: 3.240

5.  Chronic microsensors for longitudinal, subsecond dopamine detection in behaving animals.

Authors:  Jeremy J Clark; Stefan G Sandberg; Matthew J Wanat; Jerylin O Gan; Eric A Horne; Andrew S Hart; Christina A Akers; Jones G Parker; Ingo Willuhn; Vicente Martinez; Scott B Evans; Nephi Stella; Paul E M Phillips
Journal:  Nat Methods       Date:  2009-12-27       Impact factor: 28.547

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.