Effect of local limb temperature on pulse oximetry and the plethysmographic pulse wave.

W M Schramm1, A Bartunek, H Gilly.   

Abstract

We attempted to evaluate prospectively local thermoregulatory vasoconstriction and vasodilatation in 15 volunteers by means of pulse oximetry and plethysmography as measured by a finger tip-pulse oximeter. Recent studies [1] concluded that the plethysmo time interval (PTI) between the QRS complex on ECG and the upstroke of the plethysmographic wave of the pulse oximeter is useful in evaluating the peripheral circulatory status. Venous (both Vv cubitae) blood samples for determination of SvO2 were drawn, as well as pulse oximetry SpO2 oxygen saturation measurements and calculation of PTI were performed under conditions of normothermia, hypothermia and hyperthermia, before and after immersing the hands of the volunteers in a cold (15 degrees C) and warm (45 degrees C) waterbath. Two pulse oximeters simultaneously were used, one for each hand, in order to check to which extent SpO2, SvO2 and PTI might be influenced by gross limb temperature changes. Our results show that during local hyperthermia SpO2 significantly decreased and during local hypothermia SpO2 increased after immersing the one hand in a warm waterbath and the other hand in a cold waterbath at the same time. The peripheral SvO2 significantly increased in the warm hand and decreased in the cold hand. PTI remained unchanged after exposure to either a cold or a warm waterbath. The possibility of technical causes for the SpO2 changes were eliminated. Finger-tip pulse oximetry SpO2 readings change with limb temperature. The change in venous oxygen saturation can be explained by temperature dependent arteriovenous shunts in the periphery. The observed change in SpO2 probably reflects altered transmission of arterial pulsations to venous blood in the finger.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9127780     DOI: 10.1007/bf03356574

Source DB:  PubMed          Journal:  Int J Clin Monit Comput        ISSN: 0167-9945


  7 in total

1.  Effect of peripheral vasoconstriction on pulse oximetry.

Authors:  Pekka Talke; Claudia Stapelfeldt
Journal:  J Clin Monit Comput       Date:  2006-07-14       Impact factor: 2.502

2.  Can the descending aortic stroke volume be estimated by transesophageal descending aortic photoplethysmography?

Authors:  Peng Ling; Gong Quan; Yu Siyuan; Gao Bo; Wei Wei
Journal:  J Anesth       Date:  2017-03-27       Impact factor: 2.078

3.  Effects of mild whole body hypothermia on self-paced exercise performance.

Authors:  Steven A H Ferguson; Neil D Eves; Brian D Roy; Gary J Hodges; Stephen S Cheung
Journal:  J Appl Physiol (1985)       Date:  2018-04-19

4.  A Four-Way Comparison of Cardiac Function with Normobaric Normoxia, Normobaric Hypoxia, Hypobaric Hypoxia and Genuine High Altitude.

Authors:  Christopher John Boos; John Paul O'Hara; Adrian Mellor; Peter David Hodkinson; Costas Tsakirides; Nicola Reeve; Liam Gallagher; Nicholas Donald Charles Green; David Richard Woods
Journal:  PLoS One       Date:  2016-04-21       Impact factor: 3.240

5.  Is pulse oximeter a reliable tool for non-critically ill patients with COVID-19?

Authors:  Aslıhan Gürün Kaya; Miraç Öz; İrem Akdemir Kalkan; Ezgi Gülten; Güle Çınar; Alpay Azap; Akın Kaya
Journal:  Int J Clin Pract       Date:  2021-10-21       Impact factor: 3.149

Review 6.  Pulse oximetry: fundamentals and technology update.

Authors:  Meir Nitzan; Ayal Romem; Robert Koppel
Journal:  Med Devices (Auckl)       Date:  2014-07-08

7.  Comparison of forehead and finger oximetry sensors during the six minute walk test.

Authors:  Lucy Robertson; Rachel Lowry; Karl Sylvester; Helen Parfrey; Beverley Moseley; Karen Sheares; Katrina Oates
Journal:  Chron Respir Dis       Date:  2022 Jan-Dec       Impact factor: 2.444

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.