Literature DB >> 9127450

Automatic calculation of three-dimensional margins around treatment volumes in radiotherapy planning.

J C Stroom1, P R Storchi.   

Abstract

Following the publication of ICRU Report 50, the concepts of GTV (gross tumour volume). CTV (clinical target volume) and PTV (planning target volume) are being used in radiotherapy planning with increasing frequency. In 3D planning, the GTV (or CTV) is normally outlined by the clinician in CT or MRI slices. The PTV is determined by adding margins to these volumes. Since manual drawing of an accurate 3D margin in a set of 2D slices is extremely time consuming, software has been developed to automate this step in the planning. The target volume is represented in a 3D matrix grid with voxel values one inside and zero outside the target volume. It is expanded by centering an ellipsoid at every matrix element within the volume. The shape of the ellipsoid reflects the size of the margins in the three main orthogonal directions. Finally, the PTV contours are determined from the 50% iso-value lines of the expanded volume. The software tool has been in clinical use since the end of 1994 and has mostly been applied to the planning of prostate irradiations. The accuracy is better than can be achieved manually and the workload has been reduced considerably (from 4 h manually to approximately 1 min automatically).

Entities:  

Mesh:

Year:  1997        PMID: 9127450     DOI: 10.1088/0031-9155/42/4/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  A simple method of evaluating margin-growing accuracy in image-guided radiation therapy.

Authors:  Ying Wang; Fu Jin; Juan Zhou; Huanli Luo
Journal:  Br J Radiol       Date:  2016-03-23       Impact factor: 3.039

2.  Effect of intrafraction adaptation on PTV margins for MRI guided online adaptive radiotherapy for rectal cancer.

Authors:  Chavelli M Kensen; Tomas M Janssen; Anja Betgen; Lisa Wiersema; Femke P Peters; Peter Remeijer; Corrie A M Marijnen; Uulke A van der Heide
Journal:  Radiat Oncol       Date:  2022-06-21       Impact factor: 4.309

3.  Observation of interfractional variations in lung tumor position using respiratory gated and ungated megavoltage cone-beam computed tomography.

Authors:  Jenghwa Chang; Gig S Mageras; Ellen Yorke; Fernando De Arruda; Jussi Sillanpaa; Kenneth E Rosenzweig; Agung Hertanto; Hai Pham; Edward Seppi; Alex Pevsner; C Clifton Ling; Howard Amols
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-04-01       Impact factor: 7.038

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.