Analysis of atrial sensed far-field ventricular signals: a reassessment.

J Brouwer1, D Nagelkerke, P den Heijer, J H Ruiter, H Mulder, M J Begemann, K I Lie.   

Abstract

Accurate detection of the spontaneous far-field ventricular signal may be used to determine the ventricular activation, and hence, the interval from atrial stimulus to the ventricular R wave (AR interval) using a standard atrial pacing lead. This can be useful in developing a physiological atrial rate responsive (AAIR) pacemaker and in further improving DDD(R) pacing algorithms. In order to better characterize the atrial sensed far-field ventricular signal, 200 consecutive patients undergoing pacemaker implantation were studied. The amplitude of the far-field ventricular signal was significantly smaller than that of the atrial deflection. In all recordings, the slew rate of the atrial deflection was larger than that of the far-field ventricular signal. Subdivision of the recordings by electrode position, pocket location, or QRS duration on the surface ECG resulted in significantly different signal characteristics. The amplitude and slew rate of the far-field ventricular signal were significantly smaller in bipolar versus unipolar sensing. Atrial sensed far-field ventricular recordings could also be obtained in the case of ventricular pacing. Our results indicate that accurate sensing of the far-field ventricular signal from an atrial pacing lead is conceivable in most patients. The different signal characteristics in relation to parameters, such as electrode position, sensing mode, and pocket location, may be useful in determining the optimal conditions for signal sensing.

Entities:  

Mesh:

Year:  1997        PMID: 9127396     DOI: 10.1111/j.1540-8159.1997.tb05494.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  7 in total

1.  Optimal positioning of temporary epicardial atrial pacing leads after cardiac surgery.

Authors:  I Kashima; H Shin; R Yozu; S Kawada
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2001-05

Review 2.  A reappraisal of pacemaker timing cycles pertaining to automatic mode switching.

Authors:  R X Stroobandt; S S Barold; F D Vandenbulcke; R J Willems; A F Sinnaeve
Journal:  J Interv Card Electrophysiol       Date:  2001-12       Impact factor: 1.900

3.  Atrial near-field and ventricular far-field analysis by automated signal processing at rest and during exercise.

Authors:  Frank Eberhardt; Hendrik Bonnemeier; Martin Lipphardt; Ulrich G Hofmann; Heribert Schunkert; Uwe K H Wiegand
Journal:  Ann Noninvasive Electrocardiol       Date:  2006-04       Impact factor: 1.468

4.  Far field R-wave sensing in Myotonic Dystrophy type 1: right atrial appendage versus Bachmann's bundle region lead placement.

Authors:  Vincenzo Russo; Gerardo Nigro; Andrea Antonio Papa; Anna Rago; Federica Di Meo; Anna Cristiano; Antonio Molino; Raffaele Calabrò; Maria Giovanna Russo; Luisa Politano
Journal:  Acta Myol       Date:  2014-10

5.  Deterministic splicing of Dscam2 is regulated by Muscleblind.

Authors:  Joshua Shing Shun Li; S Sean Millard
Journal:  Sci Adv       Date:  2019-01-16       Impact factor: 14.136

Review 6.  The role of pacing in rhythm control and management of atrial fibrillation.

Authors:  John Silberbauer; Neil Sulke
Journal:  J Interv Card Electrophysiol       Date:  2007-05-02       Impact factor: 1.759

7.  Ambulatory Holter monitoring in asymptomatic patients with DDD pacemakers - do we need ACC/AHA Guidelines revision?

Authors:  Michal Chudzik; Artur Klimczak; Jerzy Krzysztof Wranicz
Journal:  Arch Med Sci       Date:  2013-11-05       Impact factor: 3.318