Literature DB >> 9126938

Use of Voigt lineshape for quantification of in vivo 1H spectra.

I Marshall1, J Higinbotham, S Bruce, A Freise.   

Abstract

Quantification of NMR visible metabolites by spectral modeling usually assumes a Lorentzian or Gaussian lineshape, despite the fact that experimental lineshapes are neither. To minimize systematic fitting errors, a mixed Lorentzian-Gaussian (Voigt) lineshape model was developed. When tested with synthetic FIDs, the Voigt lineshape model gave more accurate results (maximum error 2%) than either Lorentzian (maximum error 20%) or Gaussian models (maximum error 12%). The three lineshape models gave substantially different peak areas in an in vitro experiment, with the Voigt model having a much lower chi2 (2.1 compared with 5.2 for the Lorentzian model and 6.2 for the Gaussian model). In a group of 10 healthy volunteers, fitting of 1H spectra from cerebral white matter gave significantly different peak areas between the methods. Even when area ratios were taken, the Lorentzian model gave higher values (+5% for NAA/choline and +2% for NAA/creatine) than the Voigt lineshape model, whereas the Gaussian model gave lower values (-2% and -1%, respectively).

Entities:  

Mesh:

Year:  1997        PMID: 9126938     DOI: 10.1002/mrm.1910370504

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

1.  Phase-adjusted echo time (PATE)-averaging 1 H MRS: application for improved glutamine quantification at 2.89 T.

Authors:  Andrew P Prescot; Todd Richards; Stephen R Dager; Changho Choi; Perry F Renshaw
Journal:  NMR Biomed       Date:  2012-03-12       Impact factor: 4.044

2.  Image-guided spatial localization of heterogeneous compartments for magnetic resonance.

Authors:  Li An; Jun Shen
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

3.  Fast quantification of proton magnetic resonance spectroscopic imaging with artificial neural networks.

Authors:  Himanshu Bhat; Balasrinivasa Rao Sajja; Ponnada A Narayana
Journal:  J Magn Reson       Date:  2006-09-01       Impact factor: 2.229

4.  Reliable quantification of marrow fat content and unsaturation level using in vivo MR spectroscopy.

Authors:  Kaipin Xu; Sigurdur Sigurdsson; Vilmundur Gudnason; Trisha Hue; Ann Schwartz; Xiaojuan Li
Journal:  Magn Reson Med       Date:  2017-07-16       Impact factor: 4.668

5.  NMR-derived models of amidopyrine and its metabolites in complexes with rabbit cytochrome P450 2B4 reveal a structural mechanism of sequential N-dealkylation.

Authors:  Arthur G Roberts; Sara E A Sjögren; Nadezda Fomina; Kathy T Vu; Adah Almutairi; James R Halpert
Journal:  Biochemistry       Date:  2011-03-04       Impact factor: 3.162

6.  Two-dimensional J-resolved proton MR spectroscopy and prior knowledge fitting (ProFit) in the frontal and parietal lobes of healthy volunteers: assessment of metabolite discrimination and general reproducibility.

Authors:  Andrew P Prescot; Perry F Renshaw
Journal:  J Magn Reson Imaging       Date:  2012-10-10       Impact factor: 4.813

7.  A protocol for quantifying cardiogenic oscillations in dynamic 129 Xe gas exchange spectroscopy: The effects of idiopathic pulmonary fibrosis.

Authors:  Elianna A Bier; Scott H Robertson; Geoffry M Schrank; Craig Rackley; Joseph G Mammarappallil; Sudarshan Rajagopal; H Page McAdams; Bastiaan Driehuys
Journal:  NMR Biomed       Date:  2018-11-20       Impact factor: 4.044

8.  Phosphocreatine Levels in the Left Thalamus Decline during Wakefulness and Increase after a Nap.

Authors:  Ali Gordji-Nejad; Andreas Matusch; Shumei Li; Tina Kroll; Simone Beer; David Elmenhorst; Andreas Bauer
Journal:  J Neurosci       Date:  2018-10-03       Impact factor: 6.167

9.  γ-Amino butyric acid and glutamate abnormalities in adolescent chronic marijuana smokers.

Authors:  Andrew P Prescot; Perry F Renshaw; Deborah A Yurgelun-Todd
Journal:  Drug Alcohol Depend       Date:  2013-03-21       Impact factor: 4.492

10.  In vivo hepatic lipid quantification using MRS at 7 Tesla in a mouse model of glycogen storage disease type 1a.

Authors:  Nirilanto Ramamonjisoa; Helene Ratiney; Elodie Mutel; Herve Guillou; Gilles Mithieux; Frank Pilleul; Fabienne Rajas; Olivier Beuf; Sophie Cavassila
Journal:  J Lipid Res       Date:  2013-04-17       Impact factor: 5.922

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.