Literature DB >> 9125008

A comparison of compression ultrasound with color Doppler ultrasound for the diagnosis of symptomless postoperative deep vein thrombosis.

A W Lensing1, C I Doris, F P McGrath, A Cogo, M J Sabine, J Ginsberg, P Prandoni, A G Turpie, J Hirsh.   

Abstract

BACKGROUND: Despite advances in primary prophylaxis, venous thromboembolism still occurs in a considerable number of high-risk surgical patients. Screening with conventional ultrasound imaging to detect asymptomatic deep vein thrombosis (DVT) has been suggested as a strategy to improve management of such patients, but it is insufficiently sensitive. We evaluated the ability of color Doppler ultrasound to improve the sensitivity of compression ultrasound in the detection of asymptomatic DVT in high-risk orthopedic patients.
METHODS: We prospectively evaluated bilateral compression and color Doppler ultrasound measurements of the entire leg in 204 consecutive patients who underwent elective hip or knee replacement surgery, using contrast venography as the reference test. The sensitivity, specificity, and positive predictive value of the ultrasonography tests were determined.
RESULTS: The sensitivity, specificity, and positive predictive value (with 95% confidence intervals [CIs]) of compression ultrasound for the detection of proximal DVT were 60% (39%-81%), 96% (92%-99%), and 71% (48%-89%) respectively. The sensitivity, specificity, and positive predictive value (with 95% CIs) of compression ultrasound for the detection of calf vein thrombosis were 33% (18%-52%), 91% (83%-96%), and 58% (34%-80%), respectively. Color Doppler ultrasonography did not identify any additional proximal or calf vein thrombi to those detected by compression ultrasound alone. The sensitivity for all thrombi was 47% (95% CI, 34%-61%) with a positive predictive value of 65% (95% CI, 48%-79%).
CONCLUSIONS: Color Doppler ultrasonography has a moderate to low accuracy for the detection of DVT in patients who have had hip and knee replacement surgery. Color Doppler ultrasonography does not increase the detection rate for asymptomatic DVT over compression ultrasound and thus cannot be recommended as a screening test in this setting.

Entities:  

Mesh:

Year:  1997        PMID: 9125008

Source DB:  PubMed          Journal:  Arch Intern Med        ISSN: 0003-9926


  12 in total

1.  Compression ultrasonography for diagnosing deep vein thrombosis. One examination of whole leg is better than two of selected parts.

Authors:  D E FitzGerald; A M O'Shaughnessy
Journal:  BMJ       Date:  1998-05-16

2.  Usefulness of D-dimer, blood gas, and respiratory rate measurements for excluding pulmonary embolism.

Authors:  P Egermayer; G I Town; J G Turner; D C Heaton; A L Mee; M E Beard
Journal:  Thorax       Date:  1998-10       Impact factor: 9.139

3.  The role of ultrasonography in thromboembolic disease management in the orthopaedic patient.

Authors:  W J Ciccone; J S Reid; V D Pellegrini
Journal:  Iowa Orthop J       Date:  1999

4.  Diagnosis of deep vein thrombosis of the lower extremity: a systematic review and meta-analysis of test accuracy.

Authors:  Meha Bhatt; Cody Braun; Payal Patel; Parth Patel; Housne Begum; Wojtek Wiercioch; Jamie Varghese; David Wooldridge; Hani J Alturkmani; Merrill Thomas; Mariam Baig; Waled Bahaj; Rasha Khatib; Rohan Kehar; Rakesh Ponnapureddy; Anchal Sethi; Ahmad Mustafa; Robby Nieuwlaat; Wendy Lim; Shannon M Bates; Eddy Lang; Grégoire Le Gal; Marc Righini; Nedaa M Husainat; Mohamad A Kalot; Yazan Nayif Al Jabiri; Holger J Schünemann; Reem A Mustafa
Journal:  Blood Adv       Date:  2020-04-14

Review 5.  [Diagnostic imaging of venous disease: Part I: methods in the diagnosis of veins and thrombosis].

Authors:  K Krüger; J Wildberger; P Haage; P Landwehr
Journal:  Radiologe       Date:  2008-10       Impact factor: 0.635

Review 6.  A systematic review of the accuracy of ultrasound in the diagnosis of deep venous thrombosis in asymptomatic patients.

Authors:  Behrouz Kassaï; Jean-Pierre Boissel; Michel Cucherat; Sandrine Sonie; Nirav R Shah; Alain Leizorovicz
Journal:  Thromb Haemost       Date:  2004-04       Impact factor: 5.249

Review 7.  Point-of-care ultrasound and Doppler ultrasound evaluation of vascular injuries in penetrating and blunt trauma.

Authors:  Miguel Angel Montorfano; Fernando Pla; Leonardo Vera; Omar Cardillo; Stefano Geniere Nigra; Lisandro Miguel Montorfano
Journal:  Crit Ultrasound J       Date:  2017-02-16

Review 8.  Graduated compression stockings in hip fractures.

Authors:  A Alsawadi; M Loeffler
Journal:  Ann R Coll Surg Engl       Date:  2012-10       Impact factor: 1.891

Review 9.  Ultrasonography in the emergency department.

Authors:  Micah R Whitson; Paul H Mayo
Journal:  Crit Care       Date:  2016-08-15       Impact factor: 9.097

Review 10.  Ultrasonography in the Critical Care Unit.

Authors:  Keith Guevarra; Yonatan Greenstein
Journal:  Curr Cardiol Rep       Date:  2020-09-10       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.