Literature DB >> 9121991

Complications associated with pectoral implantation of cardioverter defibrillators. World-Wide Jewel Investigators.

M R Gold1, R W Peters, J W Johnson, S R Shorofsky.   

Abstract

Pectoral placement of ICD pulse generators is now routine after downsizing of these devices. However, the safety of this approach is not well documented. The aim of this study was to evaluate complications in a large cohort of patients undergoing initial pectoral ICD implantation. The subjects for this study were 1,000 consecutive patients receiving a Medtronic Jewel ICD at 93 centers worldwide. Cumulative follow-up for all patients was 634 patient-years, with 64.9% of patients followed for 6 months or longer. The complications evaluated were erosion, pocket hematoma, seroma, wound infection, dehiscence, device migration, lead fracture, and dislodgment. In this series, 1.8% of patients experienced a pocket complication with only 3 (0.3%) erosions and 2 (0.2%) infections. Lead complications were observed in 2.1% of subjects, most commonly early dislodgment of the RV lead. We conclude that pectoral implantation of a downsized ICD system can be performed with a low rate of complications. However, careful attention to anchoring techniques and close early monitoring is important given the 1.7% rate of lead dislodgment that occurred primarily during the first month following implantation.

Entities:  

Mesh:

Year:  1997        PMID: 9121991     DOI: 10.1111/j.1540-8159.1997.tb04844.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  7 in total

1.  The Entirely Subcutaneous Defibrillator - A New Generation and Future Expectations.

Authors:  Hussam Ali; Pierpaolo Lupo; Riccardo Cappato
Journal:  Arrhythm Electrophysiol Rev       Date:  2015-08

2.  Frozen shoulder syndrome associated with subpectoral defibrillator implantation.

Authors:  M C Burke; K Drinan; D E Kopp; J G Kall; R J Verdino; H Paydak; D J Wilber
Journal:  J Interv Card Electrophysiol       Date:  1999-10       Impact factor: 1.900

3.  Endovascular extraction techniques: Part 3: Results and indications in patients with an ICD.

Authors:  F A Bracke; A Meijer; B van Gelder
Journal:  Neth Heart J       Date:  2001-06       Impact factor: 2.380

Review 4.  Pacemaker and ICD leads: strategies for long-term management.

Authors:  P Peter Borek; Bruce L Wilkoff
Journal:  J Interv Card Electrophysiol       Date:  2008-04-08       Impact factor: 1.900

5.  Complications and mortality of single versus dual chamber implantable cardioverter defibrillators.

Authors:  Ataallah Bagherzadeh; Zahra Emkanjoo; Majid Haghjoo; Maryam Moshkani Farahani; Abolfath Alizadeh; Mohammad Ali Sadr-Ameli
Journal:  Indian Pacing Electrophysiol J       Date:  2006-04-01

6.  2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing.

Authors:  Bruce L Wilkoff; Laurent Fauchier; Martin K Stiles; Carlos A Morillo; Sana M Al-Khatib; Jesœs Almendral; Luis Aguinaga; Ronald D Berger; Alejandro Cuesta; James P Daubert; Sergio Dubner; Kenneth A Ellenbogen; N A Mark Estes; Guilherme Fenelon; Fermin C Garcia; Maurizio Gasparini; David E Haines; Jeff S Healey; Jodie L Hurtwitz; Roberto Keegan; Christof Kolb; Karl-Heinz Kuck; Germanas Marinskis; Martino Martinelli; Mark McGuire; Luis G Molina; Ken Okumura; Alessandro Proclemer; Andrea M Russo; Jagmeet P Singh; Charles D Swerdlow; Wee Siong Teo; William Uribe; Sami Viskin; Chun-Chieh Wang; Shu Zhang
Journal:  J Arrhythm       Date:  2016-02-01

7.  Placement Of Cardiac PacemaKEr Trial (POCKET) - rationale and design: a randomized controlled trial.

Authors:  Peter Magnusson; Leo Wennström; Robert Kastberg; Per Liv
Journal:  Heart Int       Date:  2017-04-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.