Literature DB >> 9120979

Electrosurgery for routine pediatric penile procedures.

K M Peters1, E J Kass.   

Abstract

PURPOSE: Traditional teaching in urology has been to avoid electrosurgical devices in penile surgical procedures. In the last several years cutting current has been routinely used on the penis for making skin incisions, degloving, creating Byars flaps and destroying skin bridges. The purpose of this study was to determine the complications and final outcomes of electro-surgery.
MATERIALS AND METHODS: A 5-year retrospective chart review was done to determine the complications and final outcomes of exclusively using electrical current to perform pediatric penile procedures.
RESULTS: Electrosurgery was used to perform the entire surgical dissection in 346 patients, including circumcision in 124, repeat circumcision in 68, penoscrotal fusion/chordee repair in 127 and skin bridge procedures in 27. All patients had a satisfactory cosmetic result. After correction of penoscrotal fusion, separation at the scrotal suture line in 2 patients healed secondarily without sequelae. There was no hematoma, tissue necrosis or skin sloughing and all surgery was performed on an outpatient basis.
CONCLUSIONS: Electrosurgery can be used safely and effectively for routine penile procedures, providing a bloodless operative field and excellent cosmetic results.

Entities:  

Mesh:

Year:  1997        PMID: 9120979

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  5 in total

1.  Circumcision: a refined technique and 5 year review.

Authors:  S C Tucker; J Cerqueiro; G D Sterne; A Bracka
Journal:  Ann R Coll Surg Engl       Date:  2001-03       Impact factor: 1.891

2.  Circumcision using bipolar diathermy scissors: a simple, safe and acceptable new technique.

Authors:  I D Fraser; J Tjoe
Journal:  Ann R Coll Surg Engl       Date:  2000-05       Impact factor: 1.891

3.  Revisions after unsatisfactory adult circumcisions.

Authors:  Ferenc Fekete; Alexander Török; Peter Nyirády
Journal:  Int Urol Nephrol       Date:  2010-09-29       Impact factor: 2.370

4.  Paediatric circumcision using bipolar diathermy.

Authors:  Robert T Peters; Ross Fisher
Journal:  Ann R Coll Surg Engl       Date:  2009-07       Impact factor: 1.891

Review 5.  Electrosurgery use in circumcision in children: Is it safe?

Authors:  Tariq Ibrahim Altokhais
Journal:  Urol Ann       Date:  2017 Jan-Mar
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.