Literature DB >> 9119826

Extended Willis circle model to explain clinical observations in periorbital arterial flow.

A Viedma1, C Jiménez-Ortiz, V Marco.   

Abstract

A fluid-dynamic model of the circle of Willis and its periorbital links with the external carotid arteries has been established and tested. It is based on anatomic data and takes Doppler measurements as flow input conditions. The model explains, on fluid-dynamic grounds, the clinical observations of periorbital reverse flow and arrival pulse time delay. It also obtains the velocity and pressure pulse at any point of the studied area. This allows the comparison between the normal or healthy condition and the flow distribution when an internal carotid is externally or pathologically occluded. Several combinations of the communicating artery sizes are explored to obtain the reduced cerebral flow. The combination of the communicating diameters can lead to insufficient irrigation which can be hydrodynamically assessed. No other physiological response is included, and the results must be considered as a minimum assured. These results show the need for a common evaluation of the alternative paths and explain some paradoxes found in literature.

Entities:  

Mesh:

Year:  1997        PMID: 9119826     DOI: 10.1016/s0021-9290(96)00143-1

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

1.  Assessment of the collateral function of the circle of Willis: three-dimensional time-of-flight MR angiography compared with transcranial color-coded duplex sonography.

Authors:  Arjan W J Hoksbergen; Charles B L Majoie; Frans-Jan H Hulsmans; Dink A Legemate
Journal:  AJNR Am J Neuroradiol       Date:  2003-03       Impact factor: 3.825

2.  BLOOD FLOW IN THE CIRCLE OF WILLIS: MODELING AND CALIBRATION.

Authors:  Kristen Devault; Pierre A Gremaud; Vera Novak; Mette S Olufsen; Guillaume Vernières; Peng Zhao
Journal:  Multiscale Model Simul       Date:  2008-01-27       Impact factor: 1.930

3.  Studying the Factors of Human Carotid Atherosclerotic Plaque Rupture, by Calculating Stress/Strain in the Plaque, Based on CEUS Images: A Numerical Study.

Authors:  Zhenzhou Li; Yongfeng Wang; Xinyin Wu; Xin Liu; Shanshan Huang; Yi He; Shuyu Liu; Lijie Ren
Journal:  Front Neuroinform       Date:  2020-11-24       Impact factor: 4.081

4.  Application of Linear Gradient Magnetic Field in Arterial Profile Scanning Imaging.

Authors:  Yanjun Liu; Guoqiang Liu; Dan Yang; Bin Xu
Journal:  Sensors (Basel)       Date:  2020-08-13       Impact factor: 3.576

5.  Numerical Simulation of the blood flow behavior in the circle of  Willis.

Authors:  Seyyed Esmail Razavi; Rana Sahebjam
Journal:  Bioimpacts       Date:  2014-06-30

6.  The role of the circle of Willis in internal carotid artery stenosis and anatomical variations: a computational study based on a patient-specific three-dimensional model.

Authors:  Guangyu Zhu; Qi Yuan; Jian Yang; Joon Hock Yeo
Journal:  Biomed Eng Online       Date:  2015-11-25       Impact factor: 2.819

  6 in total