Telemetry of forces from proximal femoral replacements and relevance to fixation.

S J Taylor1, J S Perry, J M Meswania, N Donaldson, P S Walker, S R Cannon.   

Abstract

Two proximal femoral replacements were instrumented to enable axial forces to be determined at two sites within the prosthesis: in the main shaft and near the tip of the intramedullary stem. The goal was to measure the changes in force distribution over time, as indicated by the ratio of the two forces. Inductive coupling between a coil worn around the leg and a small implanted coil was used, both to supply power to electronic circuits sealed into a welded cavity in the prosthesis and to telemeter data from the prosthesis. Data from both subjects were recorded over the first two years following surgery. For the first subject, there was an increase in mean shaft force excursions (peak force minus resting force) during level walking from 0.53 x BW after 1 week 2.77 x BW after 23 months. The corresponding mean tip force excursions were 0.13 x BW and 1.74 x BW, respectively. The ratio of mean tip force excursions to shaft force excursions steadily increased over the same period from 25 to 63%. Similar increases over time in the tip/shaft ratio were found during treadmill walking, stair climbing and stair descending. Data from the second subject were obtained for the shaft forces only, and were consistent with those from the first subject. The progressive transfer of axial load from the proximal to the distal part of the IM stem recorded telemetrically, together with radiographic observations, suggested that bone remodelling had taken place together with a less stable interface around the proximal part of the stem. This process evidently began soon after implantation.

Entities:  

Mesh:

Year:  1997        PMID: 9119821     DOI: 10.1016/s0021-9290(96)00141-8

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  12 in total

1.  Hydroxyapatite-coated collars reduce radiolucent line progression in cemented distal femoral bone tumor implants.

Authors:  Melanie J Coathup; Anish Sanghrajka; William J Aston; Panagiotis D Gikas; Robin C Pollock; Stephen R Cannon; John A Skinner; Timothy W R Briggs; Gordon W Blunn
Journal:  Clin Orthop Relat Res       Date:  2015-01-30       Impact factor: 4.176

2.  Bone Plug Versus Suture-Only Fixation of Meniscal Grafts: Effect on Joint Contact Mechanics During Simulated Gait.

Authors:  Hongsheng Wang; Albert O Gee; Ian D Hutchinson; Kirsten Stoner; Russell F Warren; Tony O Chen; Suzanne A Maher
Journal:  Am J Sports Med       Date:  2014-04-28       Impact factor: 6.202

3.  Dynamic contact mechanics on the tibial plateau of the human knee during activities of daily living.

Authors:  Susannah Gilbert; Tony Chen; Ian D Hutchinson; Dan Choi; Clifford Voigt; Russell F Warren; Suzanne A Maher
Journal:  J Biomech       Date:  2013-11-16       Impact factor: 2.712

4.  Compliant Compression Reconstruction of the Proximal Femur Is Durable Despite Minimal Bone Formation in the Compression Segment.

Authors:  Alexander B Christ; Tomohiro Fujiwara; Nicola Fabbri; John H Healey
Journal:  Clin Orthop Relat Res       Date:  2021-07-01       Impact factor: 4.755

5.  Compression or tension? The stress distribution in the proximal femur.

Authors:  K E Rudman; R M Aspden; J R Meakin
Journal:  Biomed Eng Online       Date:  2006-02-20       Impact factor: 2.819

6.  Postoperative changes in in vivo measured friction in total hip joint prosthesis during walking.

Authors:  Philipp Damm; Alwina Bender; Georg Bergmann
Journal:  PLoS One       Date:  2015-03-25       Impact factor: 3.240

7.  Osteointegration of hydroxyapatite-coated collars in cemented massive endoprostheses following revision surgery.

Authors:  Benjamin Davies; Rajiv Kaila; Loukas Andritsos; Christian Gray Stephens; Gordon W Blunn; Craig Gerrand; Panagiotis Gikas; Andrew Johnston
Journal:  Bone Jt Open       Date:  2021-06

8.  In vivo evaluation of edge-loading in metal-on-metal hip resurfacing patients with pseudotumours.

Authors:  Y-M Kwon; S J Mellon; P Monk; D W Murray; H S Gill
Journal:  Bone Joint Res       Date:  2012-04-01       Impact factor: 5.853

9.  High-tech hip implant for wireless temperature measurements in vivo.

Authors:  Georg Bergmann; Friedmar Graichen; Jörn Dymke; Antonius Rohlmann; Georg N Duda; Philipp Damm
Journal:  PLoS One       Date:  2012-08-22       Impact factor: 3.240

10.  Standardized loads acting in knee implants.

Authors:  Georg Bergmann; Alwina Bender; Friedmar Graichen; Jörn Dymke; Antonius Rohlmann; Adam Trepczynski; Markus O Heller; Ines Kutzner
Journal:  PLoS One       Date:  2014-01-23       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.