Literature DB >> 9117031

Inspiratory dynamic obstruction detected by forced oscillation during CPAP. A model study.

R Farré1, R Peslin, M Rotger, D Navajas.   

Abstract

Assessment of upper airway mechanics in patients with obstructive sleep apnea/hypopnea (OSA) can be carried out qualitatively from indirect signals (flow pattern, snoring, strain gauges, inductance plethysmography) or quantitatively by means of invasive estimation of esophageal pressure. The forced oscillation technique (FOT) is a noninvasive method of potential interest for quantitatively assessing airway obstruction in the sleeping patient. The aim of this work was to ascertain in a model study whether FOT could provide an index of airway obstruction when applied at the conditions of total and partial occlusions similar to the ones found in patients with OSA. An airway analog closely mimicking upper airway collapsibility was constructed and mechanically characterized by the relationship between its flow, upstream and downstream pressures as well as by means of FOT. We simulated total collapse (apnea), different levels of partial collapse with flow limitation (hypopnea), and release of airway obstruction when the collapsible analog was used as an artificial upper airway in a spontaneously breathing subject submitted to continuous positive airway pressure (CPAP) up to 14 cm H2O.s/L. The results showed that the amplitude of airway impedance measured by FOT was a suitable index to detect obstruction in collapsible segments. We concluded from this realistic model study that FOT could be a valuable tool for quantitatively assessing airway obstruction in patients with OSA treated with CPAP. This noninvasive technique is potentially useful both in studying upper airway mechanics in detail and in automatically monitoring airway obstruction in routine studies.

Entities:  

Mesh:

Year:  1997        PMID: 9117031     DOI: 10.1164/ajrccm.155.3.9117031

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  5 in total

Review 1.  Respiratory input impedance measurement: forced oscillation methods.

Authors:  D MacLeod; M Birch
Journal:  Med Biol Eng Comput       Date:  2001-09       Impact factor: 2.602

2.  Improvement of CPAP Therapy by a Self-Adjusting System.

Authors:  Katrin Pilz; Stefan Thalhofer; Philipp Meissner; Peter Dorow
Journal:  Sleep Breath       Date:  2000       Impact factor: 2.816

3.  The diagnosis value and its implication of impulse oscillometry in obstructive sleep apnea syndrome patients.

Authors:  H Liu; W Ni; J Zhao; S Xiong; Y Xu; Z Zhang
Journal:  J Tongji Med Univ       Date:  2000

4.  An Official American Thoracic Society Workshop Report: Noninvasive Identification of Inspiratory Flow Limitation in Sleep Studies.

Authors:  Sushmita Pamidi; Susan Redline; David Rapoport; Indu Ayappa; Luciana Palombini; Ramon Farre; Jason Kirkness; Jean-Louis Pépin; Olli Polo; Andrew Wellman; R John Kimoff
Journal:  Ann Am Thorac Soc       Date:  2017-07

5.  New technologies to detect static and dynamic upper airway obstruction during sleep.

Authors:  J M Montserrat; R Farré; D Navajas
Journal:  Sleep Breath       Date:  2001-12       Impact factor: 2.816

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.