Modified axial lead system in children.

P W Macfarlane, E N Coleman, A Simpson.   

Abstract

Preliminary studies have been made on the use of the modified axial lead system in infancy and childhood. A highly significant correlation between internipple distance and height suggested that internipple distance be used as an index for the selection of a template to facilitate placement of the chest electrodes (Z and X). A series of 4 triangular templates was designed. The use of a template one size too large or too small was shown not to lead to any significant error in waveform measurement. A further study showed that the reference level for the application of the praecordial electrodes should be the 5th intercostal space as for adults, but that no serious diagnostic error was likely to arise if the 4th or 6th intercostal space was chosen by mistake. A study of the Frank lead system suggested that the use of the 5th intercostal space as a reference level was more appropriate than the 4th intercostal space, which is generally adopted by users of that system. The conclusion reached was that the axial lead system is the preferred orthogonal lead system for children, with templates for 4 ranges of internipple distance (less than 10 cm; 15 to 20 cm; and less than 20 cm--adult build) being proposed to simplify electrode placement.

Entities:  

Mesh:

Year:  1977        PMID: 911562      PMCID: PMC483377          DOI: 10.1136/hrt.39.10.1102

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  12 in total

1.  THE VECTORCARDIOGRAM IN NORMAL CHILDREN.

Authors:  E P NAMIN; I A D CRUZ
Journal:  Br Heart J       Date:  1964-09

2.  EVOLUTION OF THE FRANK VECTORCARDIOGRAM IN NORMAL INFANTS.

Authors:  E P NAMIN; R A ARCILLA; I A D CRUZ; B M GASUL
Journal:  Am J Cardiol       Date:  1964-06       Impact factor: 2.778

3.  The orthogonal vectorcardiogram in 100 normal children (Frank system). With some comparative data recorded by the cube system.

Authors:  P G HUGENHOLTZ; J LIEBMAN
Journal:  Circulation       Date:  1962-11       Impact factor: 29.690

4.  Comparison of four orthogonal systems of vectorcardiography.

Authors:  P H LANGNER; R H OKADA; S R MOORE; H L FIES
Journal:  Circulation       Date:  1958-01       Impact factor: 29.690

5.  An accurate, clinically practical system for spatial vectorcardiography.

Authors:  E FRANK
Journal:  Circulation       Date:  1956-05       Impact factor: 29.690

6.  Effect of E-electrode position on Frank vectorcardiogram in children.

Authors:  B Guller; C Reeves; R E Smith
Journal:  Am Heart J       Date:  1974-10       Impact factor: 4.749

7.  Quantitation of the normal Frank and McFee-Parungao orthogonal electrocardiogram in the adolescent.

Authors:  J Liebman; M H Lee; P S Rao; W Mackay
Journal:  Circulation       Date:  1973-10       Impact factor: 29.690

8.  A modified axial lead system for orthogonal lead electrocardiography.

Authors:  P W Macfarlane
Journal:  Cardiovasc Res       Date:  1969-10       Impact factor: 10.787

9.  The corrected orthogonal electrocardiogram in normal children: McFee and Parungao lead system.

Authors:  R Gamboa; N White
Journal:  Am Heart J       Date:  1968-04       Impact factor: 4.749

10.  Digital computer analysis of the vectorcardiogram of the newborn infant. Quantitative and comparative measurement of three orthogonal lead systems.

Authors:  L E Ainger
Journal:  Circulation       Date:  1967-12       Impact factor: 29.690

View more
  1 in total

1.  Modified axial lead system in children.

Authors:  W R Pearl; P W Macfarlane; E N Coleman
Journal:  Br Heart J       Date:  1978-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.