Literature DB >> 9111952

Stability of radiofrequency magnetron sputtered calcium phosphate coatings under cyclically loaded conditions.

J G Wolke1, J P van der Waerden, K de Groot, J A Jansen.   

Abstract

The stability of radiofrequency (RF) magnetron sputtered calcium phosphate was studied under cyclically loaded conditions. The coatings were deposited on titanium bars and tested in either dry or wet conditions X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX) analysis and Fourier transform infrared (FTIR) spectroscopy were used to characterize the as-sputtered and tested coatings. XRD demonstrated that the amorphous structure after annealing at 650 C changed into a crystalline apatite structure. The residual stresses were determined by the XRD cos 2 i/i method. These residual film stresses were influenced by the coating conditions and the crystalline sputtered coating showed the presence of compressive stresses. SEM demonstrated that, after cyclic loading conditions in air, the crystalline sputter-coated Ti-6A1-4V bars showed a partial coating loss. Furthermore, in wet conditions (simulated body fluid) only the heat-treated sputter-coated bars appeared to be stable. On the other hand, the amorphous coating only showed signs of delamination in the more highly stressed regions, while in the less stressed regions a Ca-P precipitate was formed. On the basis of these results we conclude that calcium phosphate coatings subjected to cyclic loading conditions show an important difference in fatigue behaviour when tested in either dry or wet conditions.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9111952     DOI: 10.1016/s0142-9612(96)00164-0

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  5 in total

1.  Fabrication and characterization of bioactive glass coatings produced by the ion beam sputter deposition technique.

Authors:  C X Wang; Z Q Chen; M Wang
Journal:  J Mater Sci Mater Med       Date:  2002-03       Impact factor: 3.896

2.  Evaluation of the tissue reaction to a percutaneous access device using titanium fibre mesh anchorage in goats.

Authors:  M Gerritsen; Y G Paquay; J A Jansen
Journal:  J Mater Sci Mater Med       Date:  1998-09       Impact factor: 3.896

3.  Osteoblast-like cell response to calcium phosphate coating chemistry and morphology on etched silicon surfaces.

Authors:  George A Burke; Chris J Rea; Fergal G Horgan; Marie Turkington; Adrian R Boyd; Brian J Meenan
Journal:  J Mater Sci Mater Med       Date:  2012-03       Impact factor: 3.896

4.  Electrochemical and mechanical behavior of laser processed Ti-6Al-4V surface in Ringer's physiological solution.

Authors:  Raghuvir Singh; S K Tiwari; Suman K Mishra; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2011-06-10       Impact factor: 3.896

5.  Calcium orthophosphate coatings, films and layers.

Authors:  Sergey V Dorozhkin
Journal:  Prog Biomater       Date:  2012-09-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.