Literature DB >> 9111402

Skin surface pressure beneath an above-the-knee cast: plaster casts compared with fiberglass casts.

J R Davids1, S L Frick, E Skewes, D W Blackhurst.   

Abstract

Complications related to immobilization in a cast after an injury or an operation may be related to the materials used for the cast or to the techniques of application, or to both. To evaluate the widely held clinical opinion that the use of a fiberglass cast is dangerous and inappropriate when subsequent swelling of the extremity is anticipated, we studied the skin surface pressures that were generated beneath above-the-knee casts made with different materials and applied with different techniques. A prosthetic model of the lower extremity was designed with an expandable calf compartment to simulate swelling after an injury or an operation. With use of this model, we measured the skin surface pressure beneath a plaster-of-Paris cast, a fiberglass cast that had been applied with a standard technique, and a fiberglass cast that had been applied with a stretch-relax technique. The highest mean skin surface pressure after application of the cast (p < 0.001) and after simulated swelling of the limb (p = 0.04) was generated by the fiberglass cast that had been applied with a standard technique. The lowest mean skin surface pressure after application of the cast (p = 0.006), simulated swelling of the limb (p < 0.001), and all subsequent steps of the experimental protocol (p < 0.001) was generated by the fiberglass cast that had been applied with the stretch-relax technique. The mean skin surface pressure generated by the plaster cast and by the fiberglass cast applied with the standard technique did not return to the value before application of the cast until anterior and posterior longitudinal cuts had been made in the cast and the cast had been spread at those cuts. When the fiber-glass cast had been applied with the stretch-relax technique, the mean pressure returned to the baseline value after only an anterior longitudinal cut and spreading at that cut. The principal pitfall of the use of a fiberglass cast is related to the technique of application. When the fiberglass cast had been applied with the standard technique, it generated a mean skin surface pressure that was higher than that associated with the plaster cast and it accommodated simulated swelling poorly. When the fiberglass cast had been properly applied, with the stretch-relax technique, it generated a mean skin surface pressure that was significantly lower (p = 0.006) than that associated with the plaster cast and it better accommodated simulated swelling without the need to sacrifice the structural integrity of the cast.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9111402     DOI: 10.2106/00004623-199704000-00013

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  8 in total

1.  Impact of Casting and Splinting Manipulations on Below-Dressing Pressures: An Experimental Model.

Authors:  Nikhil Adapa; Kanu S Goyal
Journal:  Hand (N Y)       Date:  2018-09-06

2.  Sensor-based assessment of cast placement and removal.

Authors:  Anne-Lise D Maag; Shlomi Laufer; Calvin Kwan; Elaine R Cohen; Rachel L Lenhart; Natalie C Stork; Matthew A Halanski; Carla M Pugh
Journal:  Stud Health Technol Inform       Date:  2014

3.  Evaluation of cast creep occurring during simulated clubfoot correction.

Authors:  Tamara L Cohen; Haluk Altiok; Mei Wang; Linda M McGrady; Joseph Krzak; Adam Graf; Sergey Tarima; Peter A Smith; Gerald F Harris
Journal:  Proc Inst Mech Eng H       Date:  2013-04-26       Impact factor: 1.617

4.  To Cast, to Saw, and Not to Injure: Can Safety Strips Decrease Cast Saw Injuries?

Authors:  Natalie C Stork; Rachel L Lenhart; Blaise A Nemeth; Kenneth J Noonan; Matthew A Halanski
Journal:  Clin Orthop Relat Res       Date:  2016-02-04       Impact factor: 4.176

5.  Lower limb intracast pressures generated by different types of immobilisation casts.

Authors:  Salma Chaudhury; Alexandra Hazlerigg; Anuhya Vusirikala; Joseph Nguyen; Stuart Matthews
Journal:  World J Orthop       Date:  2017-02-18

Review 6.  Does the location of short-arm cast univalve effect pressure of the three-point mould?

Authors:  Blake K Montgomery; Kenneth H Perrone; Su Yang; Nicole A Segovia; Lawrence Rinsky; Carla M Pugh; Steven L Frick
Journal:  J Child Orthop       Date:  2020-06-01       Impact factor: 1.548

7.  Conservative treatment using a sponge cast for transfer fractures in nursing home patients.

Authors:  Hong Man Cho; Joon Soo Ha; Jae Woong Seo; Hyun Ju Lee; Sun Do Kim; Hyochoon Lee; Hyung Bae Park
Journal:  Clin Interv Aging       Date:  2019-07-26       Impact factor: 4.458

8.  Factors contributing to the temperature beneath plaster or fiberglass cast material.

Authors:  Michael J Hutchinson; Mark R Hutchinson
Journal:  J Orthop Surg Res       Date:  2008-02-25       Impact factor: 2.359

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.