Literature DB >> 9111260

Increased vascular resistance for venous outflow in central retinal vein occlusion.

G Michelson1, J Harazny.   

Abstract

PURPOSE: The authors quantified the vascular resistance for venous outflow in central retinal vein occlusion (CRVO).
METHODS: The blood velocity in the central retinal vein (CRV) and central retinal artery (CRA) was measured by pulsed Doppler sonography (4-Mhz probe), and the pulse curve of the intraocular pressure (IOP) was evaluated by pneumotonometry. With multichannel data acquisition and storage software, the velocity-pulse curve of the CRV and CRA, the IOP-pulse curve, the arterial blood pressure, and the electrocardiogram were measured simultaneously in real-time mode. The relationships between the pulse curves of the blood velocity in the CRV and CRA and the IOP were calculated off-line. The onset time, the time of half maximum, and the time to the maximum of the pulse curves were evaluated. A relative index R' for the retinal outflow resistance was calculated by R' = deltaIOP/deltaVcrv. The authors examined 23 eyes of 23 patients with CRVO not older than 2 weeks and 23 eyes of 23 age-matched controls. There was no significant difference between the mean age of the control group (46 +/- 16 years) and that of the CRVO group (54 +/- 20 years).
RESULTS: In eyes with CRVO, the authors found significantly lower systolic, diastolic, and mean outflow velocity. The amplitude of the CRV velocity pulse was significantly decreased compared with control eyes. In CRVO, the mean CRV velocity pulse amplitude (deltaVvein) was 1.77 +/- 1.0 cm/second, and in controls, it was 2.08 +/- 0.61 cm/second (P < 0.005). There was no significant difference in the mean IOP, but the IOP pulse amplitude (deltaIOP) was significantly higher in CRVO compared with controls (deltaIOP: CRVO 2.82 +/- 1.45 mmHg, control 1.96 +/- 0.56 mmHg, P < 0.005). The relative resistance index R' for venous outflow was significantly increased in eyes with CRVO (2.0 +/- 1.1 mmHg/cm/sec) compared with controls (1.1 +/- 0.44 mmHg/cm/s, P < 0.001).
CONCLUSION: In eyes with CRVO, the systolic, diastolic, and mean velocity and the amplitude of the CRV velocity-pulse curve were significantly decreased and the resistance for retinal venous outflow was significantly increased compared with controls.

Entities:  

Mesh:

Year:  1997        PMID: 9111260     DOI: 10.1016/s0161-6420(97)30255-3

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  4 in total

1.  Pulse waveform analysis in the optic nerve head circulation reflects systemic vascular resistance obtained via a Swan-Ganz catheter.

Authors:  Tomoaki Shiba; Mao Takahashi; Ryuya Hashimoto; Tadashi Matsumoto; Yuichi Hori
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-02-18       Impact factor: 3.117

2.  High-overtone self-focusing acoustic transducers for high-frequency ultrasonic Doppler.

Authors:  Jie Zhu; Chuangyuan Lee; Eun Sok Kim; Dawei Wu; Changhong Hu; Qifa Zhou; K Kirk Shung; Gaofeng Wang; Hongyu Yu
Journal:  Ultrasonics       Date:  2010-02-08       Impact factor: 2.890

3.  Systolodiastolic variations of blood flow during central retinal vein occlusion: exploration by dynamic angiography.

Authors:  M Paques; O Baillart; O Genevois; A Gaudric; B I Lévy; J Sahel
Journal:  Br J Ophthalmol       Date:  2005-08       Impact factor: 4.638

4.  Relationship between retinal blood flow and cytokines in central retinal vein occlusion.

Authors:  Hidetaka Noma; Kanako Yasuda; Tatsuya Mimura; Akemi Ofusa; Masahiko Shimura
Journal:  BMC Ophthalmol       Date:  2020-06-05       Impact factor: 2.209

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.