Literature DB >> 9107166

Nitroglycerin-augmented 201T1 reinjection enhances detection of reversible myocardial hypoperfusion. A randomized, double-blind, parallel, placebo-controlled trial.

Z X He1, R Medrano, J T Hays, J J Mahmarian, M S Verani.   

Abstract

BACKGROUND: Recent observations suggest that administration of nitrates before 201Tl reinjection enhances the detection of reversible myocardial hypoperfusion. METHODS AND
RESULTS: Ninety-six patients who underwent exercise-redistribution 201Tl single photon emission computed tomography (SPECT) and had persistent defects at 4-hour redistribution imaging were prospectively randomized into a double-blind protocol in which they received a reinjection of 201Tl (1.0 mCi) 5 minutes after either placebo or 0.8 mg sublingual nitroglycerin administration, followed by repeat SPECT imaging. Of the 69 patients who had coronary angiography, all except one had significant coronary stenoses. The overall extent of perfusion defect and the reversible component assessed by polar maps of the stress-redistribution images were similar in patients who received nitroglycerin or placebo. Among the 66 patients with persistent defects in the redistribution images, 58% of those receiving nitroglycerin showed improved reversibility after reinjection, compared with 33% of patients receiving placebo (P < .05). Among 68 patients with significant coronary stenoses, those who received nitroglycerin and had coronary collateral circulation were more likely to exhibit improved reversibility after reinjection than the remaining patients (50% versus 21%, P < .05). Moreover, the ratio of reversible to total defect in the vascular territories supplied by collaterals was > or = 0.50 after reinjection in 80% of patients who received nitroglycerin (n = 20) compared with 40% of the patients who received placebo (n = 15) (P < .05).
CONCLUSIONS: Nitrate-augmented 201Tl reinjection significantly, albeit modestly, improves detection of defect reversibility, especially in patients with coronary collateral circulation.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9107166     DOI: 10.1161/01.cir.95.7.1799

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  15 in total

1.  The role of cardiac imaging in optimizing therapy in heart failure.

Authors:  A Lahiri
Journal:  J Nucl Cardiol       Date:  2000 Jan-Feb       Impact factor: 5.952

Review 2.  The historical and conceptual evolution of radionuclide assessment of myocardial viability.

Authors:  James E Udelson; Robert O Bonow; Vasken Dilsizian
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

3.  Patient-centered imaging.

Authors:  E Gordon Depuey; John J Mahmarian; Todd D Miller; Andrew J Einstein; Christopher L Hansen; Thomas A Holly; Edward J Miller; Donna M Polk; L Samuel Wann
Journal:  J Nucl Cardiol       Date:  2012-04       Impact factor: 5.952

4.  FDG imaging should be considered the preferred technique for accurate assessment of myocardial viability: against.

Authors:  Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07       Impact factor: 9.236

Review 5.  Imaging techniques in nuclear cardiology for the assessment of myocardial viability.

Authors:  Riemer H J A Slart; Jeroen J Bax; Dirk J van Veldhuisen; Ernst E van der Wall; Rudi A J O Dierckx; Pieter L Jager
Journal:  Int J Cardiovasc Imaging       Date:  2005-12-13       Impact factor: 2.357

6.  Evaluation of myocardial viability by myocardial perfusion imaging: should nitrates be used?

Authors:  Z X He; M S Verani
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

Review 7.  Radionuclide techniques for the assessment of myocardial viability.

Authors:  E Skoufis; A I McGhie
Journal:  Tex Heart Inst J       Date:  1998

8.  Methodology of a novel myocardial viability protocol.

Authors:  A E Iskandrian; E Acio
Journal:  J Nucl Cardiol       Date:  1998 Mar-Apr       Impact factor: 5.952

Review 9.  Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation.

Authors:  Sharmila Dorbala; Karthik Ananthasubramaniam; Ian S Armstrong; Panithaya Chareonthaitawee; E Gordon DePuey; Andrew J Einstein; Robert J Gropler; Thomas A Holly; John J Mahmarian; Mi-Ae Park; Donna M Polk; Raymond Russell; Piotr J Slomka; Randall C Thompson; R Glenn Wells
Journal:  J Nucl Cardiol       Date:  2018-10       Impact factor: 5.952

10.  Tc-99m tetrofosmin tomography after nitrate administration in patients with ischemic left ventricular dysfunction: relation to metabolic imaging by PET.

Authors:  Wei He; Wanda Acampa; Ciro Mainolfi; Francesco Menna; Anna Rita Sorrentino; Mario Petretta; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2003 Nov-Dec       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.