Literature DB >> 9106773

Cardiac 18F-FDG-SPET studies in patients with non-insulin-dependent diabetes mellitus during hyperinsulinaemic euglycaemic clamping.

J J Bax1, F C Visser, P G Raymakers, A Van Lingen, J H Cornel, J M Huitink, A Elhendy, R J Heine, C A Visser.   

Abstract

Identification of viable myocardium is possible with 18F-fluorodeoxyglucose (FDG) and positron emission tomography (PET). More recently, the feasibility of cardiac FDG imaging with single photon emission tomography (SPET) has been reported. In patients with diabetes mellitus, poor image quality is frequently obtained with FDG-PET, due to relative or absolute insulin deficiency and peripheral insulin resistance. To improve image quality of the FDG-PET studies, the hyperinsulinaemic glucose clamp has been proposed. We assessed the image quality of cardiac FDG-SPET studies in 10 patients with non-insulin-dependent diabetes mellitus (NIDDM) and compared the results with those obtained in 10 patients without NIDDM. All FDG studies were performed during hyperinsulinaemic glucose clamping. Image quality was expressed as myocardial to blood pool activity (M/B) ratios. Residual viability was assessed in dysfunctional myocardium. The M/B ratios were comparable between patients with and without NIDDM (2.67 +/- 0.8 vs 2.50 +/- 0.7, N.S.). Residual viability was detected in 51% of the dysfunctional segments of the patients with NIDDM and in 49% of the segments of the patients without NIDDM. In the small subset of patients (n = 10) undergoing revascularization, 19 of 20 (95%) segments that had improved wall motion were viable on FDG-SPET. In contrast, 27 of 36 (75%) segments that did not improve were necrotic on FDG-SPET. Thus FDG-SPET during hyperinsulinaemic glucose clamping provides adequate image quality in patients with NIDDM compared with patients without NIDDM, and can be used in the detection of viable myocardium.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9106773     DOI: 10.1097/00006231-199703000-00003

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  2 in total

1.  The truncation artifact.

Authors:  Brian Wosnitzer; Ramesh Gadiraju; Gordon Depuey
Journal:  J Nucl Cardiol       Date:  2011-02       Impact factor: 5.952

2.  Low-carbohydrate diet versus euglycemic hyperinsulinemic clamp for the assessment of myocardial viability with 18F-fluorodeoxyglucose-PET: a pilot study.

Authors:  José Soares; Filadelfo Rodrigues Filho; Marisa Izaki; Maria Clementina P Giorgi; Rosa M A Catapirra; Rubens Abe; Carmen G C M Vinagre; Giovanni G Cerri; José Cláudio Meneghetti
Journal:  Int J Cardiovasc Imaging       Date:  2013-11-20       Impact factor: 2.357

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.