Anterior instrumentation of the thoracolumbar spine. A biomechanical comparison.

J C Dick1, D S Brodke, T A Zdeblick, B D Bartel, D N Kunz, A J Rapoff.   

Abstract

STUDY
DESIGN: To evaluate the fatigue strength and stiffness of four anterior thoracolumbar fixation devices using a corpectomy model without load-sharing bone graft to test the devices under the worst case scenario of instability.
OBJECTIVES: To gain a more thorough understanding of the biomechanical qualities of anterior fixation devices to improve clinical application and design. SUMMARY OF BACKGROUND DATA: For many surgeons, the anterior approach has become the treatment of choice for patients with compression of the spinal cord, whether it is caused by trauma, tumor, or infection. When stabilization is needed, anterior fixation devices have been advocated for many years to avoid the additional approach required for posterior fixation. Many of these devices, however, have an unacceptably high rate of hardware failure. Recently, several new devices for anterior fixation have been marketed with purported advantages in fatigue life and ease of use.
METHODS: Four implants, the Synthes Anterior Thoracolumbar Locking Plate, the Kaneda device, a Texas Scottish Rite Hospital anterior construct, and the Z-Plate were attached to vertebral models and tested for stiffness in multiple planes on a modified Materials Testing System machine. They then were fatigued to failure on an Instron testing machine.
RESULTS: The Anterior Thoracolumbar Locking Plate was the stiffest in axial compression, lateral flexion, and torsion. The Texas Scottish Rite Hospital anterior construct was the least stiff in flexion-extension, with no significant differences in the stiffness of the anterior thoracolumbar locking plate, that of the Kaneda device, and that of the Z-Plate. Fatigue life exceeded 80,000 cycles for the anterior thoracolumbar locking plate and averaged 26,472 cycles for the Z-Plate, 6915 cycles for the Teas Scottish Rite Hospital construct, and 4419 cycles for the Kaneda device.
CONCLUSIONS: The significantly greater fatigue life of the Anterior Thoracolumbar Locking Plate and the Z-Plate may predict a lower incidence of hardware failure than with previous anterior devices. This has been confirmed in preliminary clinical studies with the Z-Plate. Further clinical studies are needed to show if these lower failure rates will continue over a long-term period.

Entities:  

Mesh:

Year:  1997        PMID: 9106314     DOI: 10.1097/00007632-199704010-00005

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  8 in total

1.  Solvent-preserved, bovine cancellous bone blocks used for reconstruction of thoracolumbar fractures in minimally invasive spinal surgery-first clinical results.

Authors:  Markus Schultheiss; Michael Sarkar; Markus Arand; Michael Kramer; Hans-Joachim Wilke; Lothar Kinzl; Erich Hartwig
Journal:  Eur Spine J       Date:  2004-07-10       Impact factor: 3.134

2.  Influence of screw-cement enhancement on the stability of anterior thoracolumbar fracture stabilization with circumferential instability.

Authors:  Markus Schultheiss; Erich Hartwig; Lutz Claes; Lothar Kinzl; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2004-06-22       Impact factor: 3.134

3.  A history of spine biomechanics. Focus on 20th century progress.

Authors:  T R Oxland
Journal:  Unfallchirurg       Date:  2015-12       Impact factor: 1.000

4.  Two column lesions in the thoracolumbar junction: anterior, posterior or combined approach? A comparative biomechanical in vitro investigation.

Authors:  Tibor Bence; Ulrich Schreiber; Thomas Grupp; Erwin Steinhauser; Wolfram Mittelmeier
Journal:  Eur Spine J       Date:  2006-08-30       Impact factor: 3.134

5.  En bloc spondylectomy reconstructions in a biomechanical in-vitro study.

Authors:  A C Disch; K D Schaser; I Melcher; A Luzzati; F Feraboli; W Schmoelz
Journal:  Eur Spine J       Date:  2008-01-15       Impact factor: 3.134

6.  Risk factors for rod fracture after posterior correction of adult spinal deformity with osteotomy: a retrospective case-series.

Authors:  Cameron Barton; Andriy Noshchenko; Vikas Patel; Christopher Cain; Christopher Kleck; Evalina Burger
Journal:  Scoliosis       Date:  2015-11-04

7.  The Effect of Polymethyl Methacrylate Augmentation on the Primary Stability of Cannulated Bone Screws in an Anterolateral Plate in Osteoporotic Vertebrae: A Human Cadaver Study.

Authors:  Matthias Rüger; Richard M Sellei; Marcus Stoffel; Christian von Rüden
Journal:  Global Spine J       Date:  2015-06-15

8.  A Retrospective Study of 39 Patients Treated With Anterior Approach of Thoracic and Lumbar Spondylodiscitis: Clinical Manifestations, Anterior Surgical Treatment, and Outcome.

Authors:  Can Yaldz; Nail Özdemir; Onur Yaman; Hamit Günes Feran; Tugrul Tansug; Mustafa Minoglu
Journal:  Medicine (Baltimore)       Date:  2015-11       Impact factor: 1.817

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.