Literature DB >> 9105175

A dual-trap design and its applications in electrospray ionization FTICR mass spectrometry.

M V Gorshkov1, L Pasa-Tolić, J E Bruce, G A Anderson, R D Smith.   

Abstract

A new arrangement consisting of two separate Fourier transform ion cyclotron resonance (FTICR) ion traps was used to develop methods for the manipulation of the ions produced by an electrospray ionization source (ESI). A first, "accumulation" trap, is generally maintained at a higher pressure than the second, high-performance "analyzer" trap. The manipulations developed and demonstrated include the following: (1) mass-selective ion transfers between the traps; (2) mass-selective step-wise accumulation of low-abundance ions of different mass-to-charge ratios transferred from the first trap to the analyzer trap; (3) simultaneous detection of ions in the analyzer trap and ion accumulation in the source trap; (4) simultaneous ion detection in the accumulation trap and ion storage in the analyzer trap; (5) sequential multiple transfers of the ions into the analyzer trap from the same ion population stored in the accumulation trap; (6) collision-induced dissociation of ions stored in the accumulation trap followed by mass-selective transfer of the product ions into the analyzer trap; (7) sequential transfer of the ions of different mass-to-charge ratios into the analyzer trap from the same ion population stored in the accumulation trap followed by the collision-induced dissociation of transferred ions in the analyzer trap. These ion manipulations benefit multistage studies and are projected to be useful in many biochemical applications of ESI-FTICR, including structural determination of biopolymers and study of noncovalent complexes.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9105175     DOI: 10.1021/ac960941n

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Magnetic field focused ion accumulation for an internal bore liquid chromatography electrospray ionization Fourier transform ion cyclotron resonance mass spectrometer using a central trapping electrode

Authors: 
Journal:  J Am Soc Mass Spectrom       Date:  2000-06       Impact factor: 3.109

2.  Pressure limited sustained off-resonance irradiation for collision-activated dissociation in fourier transform mass spectrometry.

Authors:  M V Gorshkov; L Pasa-Tolic; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  1999-01       Impact factor: 3.109

3.  Electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry at 11.5 tesla: instrument design and initial results.

Authors:  M V Gorshkov; L Pása Tolić; H R Udseth; G A Anderson; B M Huang; J E Bruce; D C Prior; S A Hofstadler; L Tang; L Z Chen; J A Willett; A L Rockwood; M S Sherman; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  1998-07       Impact factor: 3.109

4.  Increased throughput and ultra-high mass resolution in DESI FT-ICR MS imaging through new-generation external data acquisition system and advanced data processing approaches.

Authors:  Pieter C Kooijman; Konstantin O Nagornov; Anton N Kozhinov; David P A Kilgour; Yury O Tsybin; Ron M A Heeren; Shane R Ellis
Journal:  Sci Rep       Date:  2019-01-09       Impact factor: 4.379

Review 5.  Developments in FTICR-MS and Its Potential for Body Fluid Signatures.

Authors:  Simone Nicolardi; Bogdan Bogdanov; André M Deelder; Magnus Palmblad; Yuri E M van der Burgt
Journal:  Int J Mol Sci       Date:  2015-11-13       Impact factor: 5.923

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.