What constitutes an adequate smear in fine-needle aspiration cytology of the breast?

L J Layfield1, E E Mooney, B Glasgow, S Hirschowitz, A Coogan.   

Abstract

BACKGROUND: The false-negative diagnosis is a major clinical concern and a significant cause of litigation in fine-needle aspiration cytology of breast lesions. A significant number of false-negative diagnoses may be due to inadequate sampling of these lesions. Little information is available in the literature about what constitutes an adequate specimen, and the few publications that address this issue propose criteria based on anecdotal information. Recommendations vary widely and may or may not take clinical findings into account.
METHODS: The authors studied a subgroup of 183 cases with known outcome, drawn from a series of 1779 cases, to determine the minimum number of cell clusters necessary to ensure that adequate cellular material was present for accurate diagnosis. The series included 21 cases cytologically diagnosed as false-negative, 75 cases that had been correctly identified as benign, 47 cases cytologically designated as atypical, and 40 cases that on initial review had been correctly identified as malignant. In semiblind fashion, the smears from each case were assigned to low, medium, and high cellularity categories. Low cellularity was defined as 10 or fewer cell clusters, moderate cellularity was defined as 11-30 clusters, and high cellularity was defined as more than 30 clusters. A cell cluster was defined as five or more cells. Within the low cellularity group, exact numbers of cell clusters and the presence of individual cells were recorded. The presence of bipolar cells was used as an adjunct criterion for specimen adequacy, and the bipolar cells in each of 10 x 200 fields were counted. Cellularity was then correlated with diagnostic accuracy.
RESULTS: Using a cutpoint of a cumulative score of 6 or more cell clusters or the prominence of bipolar cells (> or = 10 in each of 10 medium-power, x200 fields) for assessment of specimen adequacy, a false-negative rate of 1.5%, associated with an unsatisfactory rate of 20.2%, was obtained.
CONCLUSIONS: Based on the data gathered in this study, the authors believe that the sampling false-negative and unsatisfactory rates can be minimized by selecting a cutpoint for satisfactory smears at a level of 6 or more cell clusters (cumulative total) or the presence > or = 10 intact bipolar cells per 10 medium-power fields (x200). Use of these criteria will decrease the false-negative rate of sampling in epithelial lesions of the breast. A false-negative rate of approximately 1.5% was obtained in association with an unsatisfactory rate of 20.2%. Using a cutpoint of 1 or more cell clusters, a false-negative rate of 2.1%, associated with an unsatisfactory rate of 13.7%, was obtained.

Entities:  

Mesh:

Year:  1997        PMID: 9100536     DOI: 10.1002/(sici)1097-0142(19970225)81:1<16::aid-cncr5>3.0.co;2-e

Source DB:  PubMed          Journal:  Cancer        ISSN: 0008-543X            Impact factor:   6.860


  6 in total

1.  Cytokeratin-positive cells in the bone marrow of breast cancer patients and noncancer donors.

Authors:  David N Krag; Roberto Kusminsky; Edward Manna; Donald Weaver; Seth P Harlow; Michael Covelli; Mary A Stanley; Laurence McCahill; Frank Ittleman; Bruce Leavitt; Martin Krag; Patricia Amarante
Journal:  Appl Immunohistochem Mol Morphol       Date:  2009-10

2.  Robinson's cytological grading on aspirates of breast carcinoma: Correlation with Bloom Richardson's histological grading.

Authors:  Sk Sinha; Namita Sinha; Ranjana Bandyopadhyay; Santosh K Mondal
Journal:  J Cytol       Date:  2009-10       Impact factor: 1.000

3.  Fine needle aspiration cytology of the breast: the nonmalignant categories.

Authors:  Paulo Mendoza; Maribel Lacambra; Puay-Hoon Tan; Gary M Tse
Journal:  Patholog Res Int       Date:  2011-05-19

4.  Time for evidence-based cytology.

Authors:  Pranab Dey
Journal:  Cytojournal       Date:  2007-01-08       Impact factor: 2.091

5.  Benign pairs: a significant entity in aspiration cytology smears from breast lesions.

Authors:  Monika Rathi; Pooja Kala; Atul Gupta; Satish Kumar Budania; Harshkiran Ahuja
Journal:  Clin Med Insights Pathol       Date:  2013-11-28

6.  Comparison of specimen adequacy in fine-needle aspiration biopsies performed by surgeons and pathologists.

Authors:  Yusef M Al-Marzooq; Rajan Chopra; Ahmed T Al-Bahrani; Mohammad Younis; Abdulrahman S Al-Mulhim; Mohammed I Al-Mommatten
Journal:  Ann Saudi Med       Date:  2004 Mar-Apr       Impact factor: 1.526

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.