Literature DB >> 9099271

[Treatment of refractory glaucomas by transscleral cyclophotocoagulation using semiconductor diode laser. Analysis of 50 patients followed-up over 19 months].

P Hamard1, J M Gayraud, J Kopel, F Valtot, S Quesnot, H Hamard.   

Abstract

PURPOSE: To evaluate the effects of transscleral cyclophotocoagulation with the diode laser for refractory glaucoma with respect to intra-ocular pressure, reduction of medical therapy and complications.
METHODS: The diode laser system (Iris Medical Instrument, Oculight SLX) was used to treat 50 eyes of 47 patients with therapy resistant glaucoma and a poor prognosis with filtering surgery. All eyes had maximal hypotonic therapy and 40 (82%) patients were using carbonic anhydrase inhibitors. Laser energy was delivered to the eye through a quartz glass fiber optic probe [13 to 20 spots over 270 degrees using 3.5 J (1.75 W x 2.0 sec)]. The mean follow-up was 19.4 +/- 9.1 months (from 12 to 29 months).
RESULTS: Intra-ocular pressure significantly decreased from mean baseline 32.4 +/- 9.1 mmHg to 19.7 +/- 8.1 mmHg at the end of the follow-up (p < 0.001). An intra-ocular-pressure below 20 mmHg was obtained in 66% of the eyes. In 13 patients the carbonic anhydrase inhibitors were discontinued. Six of the 8 painful eyes had pain relief. Visual acuity decreased in 17 (34%): cataract progression in 5 eyes, uncontrolled intra-ocular-pressure in 4 eyes, glaucoma progression despite controlled intra-ocular-pressure in 3 eyes, corneal dystrophy in 3 eyes. Chronic uveitis occurred in 5 (10%) eyes. No conjonctival, scleral or direct lens damage was detected.
CONCLUSION: Contact transscleral cylophotocoagulation with the diode laser system can be successfully used to reduce intra-ocular-pressure in therapy resistant glaucoma. The incidence of complications is low with no loss of vision related to cyclodestruction.

Entities:  

Mesh:

Year:  1997        PMID: 9099271

Source DB:  PubMed          Journal:  J Fr Ophtalmol        ISSN: 0181-5512            Impact factor:   0.818


  4 in total

1.  Ultrasound Cyclo Plasty in Eyes with Glaucoma.

Authors:  Giuseppe Giannaccare; Stefano Sebastiani; Emilio C Campos
Journal:  J Vis Exp       Date:  2018-01-26       Impact factor: 1.355

2.  High-intensity focused ultrasound treatment in patients with refractory glaucoma.

Authors:  Giuseppe Giannaccare; A Vagge; C Gizzi; A Bagnis; S Sebastiani; C Del Noce; M Fresina; C E Traverso; E C Campos
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-12-03       Impact factor: 3.117

Review 3.  [Glaucoma and uveitis. Causes of and treatment options for increased intraocular pressure in cases of inflammatory ophthalmology].

Authors:  T S Dietlein
Journal:  Ophthalmologe       Date:  2003-11       Impact factor: 1.059

4.  High intensity focused ultrasound for glaucoma: 1-year results from a prospective pragmatic study.

Authors:  Raquel E Marques; Nuno P Ferreira; David C Sousa; André Diogo Barata; Paula Sens; Carlos Marques-Neves; Luis Abegão Pinto
Journal:  Eye (Lond)       Date:  2020-04-21       Impact factor: 3.775

  4 in total