Literature DB >> 9098975

Choosing sample volume to achieve maximum detection sensitivity and resolution with high-performance liquid chromatography columns of 1.0, 2.1 and 4.6 mm I.D.

S R Bakalyar1, C Phipps, B Spruce, K Olsen.   

Abstract

The relationship between sample volume and the chromatographic performance factors of detection sensitivity and resolution were explored for high-performance liquid chromatography (HPLC) columns of 1.0, 2.1 and 4.6 mm I.D. Performance was evaluated for isocratic and gradient elution in systems having low, intermediate and high extracolumn dispersion. Sample volumes ranged from 0.4 microliter to 2 ml. This paper provides guideline for selecting sample injection parameters so that the performance of microbore columns is not needlessly sacrificed by using too small or too large a sample volume. The guidelines are extracted from the works of others and are modified by our own experimental results. Comments are also made on the relative merits of various injection techniques.

Mesh:

Year:  1997        PMID: 9098975     DOI: 10.1016/s0021-9673(96)00851-5

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Temperature-assisted solute focusing with sequential trap/release zones in isocratic and gradient capillary liquid chromatography: Simulation and experiment.

Authors:  Stephen R Groskreutz; Stephen G Weber
Journal:  J Chromatogr A       Date:  2016-10-26       Impact factor: 4.759

2.  Temperature-based on-column solute focusing in capillary liquid chromatography reduces peak broadening from pre-column dispersion and volume overload when used alone or with solvent-based focusing.

Authors:  Stephen R Groskreutz; Anthony R Horner; Stephen G Weber
Journal:  J Chromatogr A       Date:  2015-06-08       Impact factor: 4.759

3.  Quantitative evaluation of models for solvent-based, on-column focusing in liquid chromatography.

Authors:  Stephen R Groskreutz; Stephen G Weber
Journal:  J Chromatogr A       Date:  2015-07-14       Impact factor: 4.759

4.  Temperature-assisted on-column solute focusing: a general method to reduce pre-column dispersion in capillary high performance liquid chromatography.

Authors:  Stephen R Groskreutz; Stephen G Weber
Journal:  J Chromatogr A       Date:  2014-05-28       Impact factor: 4.759

5.  Optimizing oxytocin LC-MS/MS sensitivity by choosing the right column.

Authors:  Mariëtte T Ackermans
Journal:  Pract Lab Med       Date:  2021-09-01

6.  Signal enhancement in supercritical fluid chromatography-diode-array detection with multiple injection.

Authors:  Mingzhe Sun; Charlotta Turner; Margareta Sandahl
Journal:  J Sep Sci       Date:  2019-11-19       Impact factor: 3.645

  6 in total