UNLABELLED: The aim of this study was to compare the accuracy and reliability of simple methods of quantifying regional cerebral blood flow (rCBF) with 123I-labeled N-isopropyl-p-iodoamphetamine (IMP) and SPECT and to determine which method was best.
METHODS: Four methods were examined: (a) the microsphere method with continuous withdrawal of arterial blood, which was based on a microsphere model using the SPECT image obtained 5 min after tracer injection, (b) the microsphere method with one-point sampling, which was the same as the first method except that one-point sampling was used instead of continuous withdrawal, (c) the modified microsphere method with one-point sampling, which was the same as the second method except that a later SPECT image (30-min postinjection) with correction was used and (d) a table look-up method based on a two-compartment model with one-point arterial blood sampling and two SPECT scans obtained 40- and 180-min postinjection. The accuracy of these methods was validated by comparing the rCBF values with those obtained by nonlinear least squares fitting analysis based on the two-compartment model in 15 subjects.
RESULTS: Regional cerebral blood flow values obtained by the first method correlated most closely with those obtained by nonlinear least squares fitting analysis (error, 6.8%). The second method estimated rCBF with a mean error of 10.4%. The third method estimated rCBF with a mean error of 13.1%, even though it tended to slightly overestimate rCBF. The fourth method was inclined to underestimate rCBF with a mean error of 17.1%, and it greatly overestimated regional distribution volume.
CONCLUSION: The first method was the most accurate and reliable. For less invasiveness, the first method should be combined with one-point sampling instead of continuous withdrawal, which was used in the second method. When using a delayed SPECT image with a conventional SPECT scanner, the third method was considered to be superior to the fourth method.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9098209

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  3 in total

1.  Quantitative measurement of regional cerebral blood flow with flow-sensitive alternating inversion recovery imaging: comparison with [iodine 123]-iodoamphetamin single photon emission CT.

Authors:  Ali Syed Arbab; Shigeki Aoki; Keiji Toyama; Nobuhiko Miyazawa; Hiroshi Kumagai; Takako Umeda; Takao Arai; Tsutomu Araki; Hiroyuki Kabasawa; Yoshiyuki Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2002-03       Impact factor: 3.825

2.  Early time points perfusion imaging: relative time of arrival, maximum derivatives and fractional derivatives.

Authors:  Kenneth K Kwong; Ona Wu; Suk-Tak Chan; Koen Nelissen; Mykhaylo Kholodov; David A Chesler
Journal:  Neuroimage       Date:  2011-05-12       Impact factor: 6.556

3.  Validation of the dual-table autoradiographic method to quantify two sequential rCBFs in a single SPET session with N-isopropyl-[123I] p-iodoamphetamine.

Authors:  Sadahiko Nishizawa; Hidehiro Iida; Tatsuro Tsuchida; Harumi Ito; Junji Konishi; Yoshiharu Yonekura
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-05-07       Impact factor: 9.236

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.