Literature DB >> 9097282

Development of a quantitative PCR assay for monitoring HCV viraemia levels in patients with chronic hepatitis C.

G Colucci1, K Gutekunst.   

Abstract

The need to improve the efficacy of anti-viral agents directed against the hepatitis C virus (HCV) has prompted the development of quantitative tests to monitor viraemia levels in relation to therapy. In this respect, we have produced a non-competitive, quantitative PCR assay (Amplicor HCV Monitor) which is based on the single, combined, reverse transcription and amplification of the 5' non-coding region of HCV RNA as well as of an internal standard which serves to assess the overall efficiency of the system. The dynamic range of the assay and its precision allows for an accurate quantification between 1000 and 1,000,000 copies of the viral genome per ml. The results of the first clinical evaluation of the test indicated that determination of viraemia may have predictive value when assessed prior to treatment, as patients with less than 50,000 HCV RNA copies per ml tend to show a long-term response to interferon-alpha (IFN-alpha) treatment. Moreover, a decrease of more than 1.5-2 logarithms occurring at 1 month post-initiation of therapy predicts response in a more timely and accurate fashion than ALT measurement. This may help in a better selection of patients to treat, therapy approaches and schedules and in the optimization of the cost-benefit balance.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9097282     DOI: 10.1111/j.1365-2893.1997.tb00164.x

Source DB:  PubMed          Journal:  J Viral Hepat        ISSN: 1352-0504            Impact factor:   3.728


  5 in total

1.  Performance of the COBAS AMPLICOR HCV MONITOR test, version 2.0, an automated reverse transcription-PCR quantitative system for hepatitis C virus load determination.

Authors:  G Gerken; T Rothaar; M G Rumi; R Soffredini; M Trippler; M J Blunk; A Butcher; S Soviero; G Colucci
Journal:  J Clin Microbiol       Date:  2000-06       Impact factor: 5.948

2.  Clinical evaluation of the automated COBAS AMPLICOR HCV MONITOR test version 2.0 for quantifying serum hepatitis C virus RNA and comparison to the quantiplex HCV version 2.0 test.

Authors:  M L Yu; W L Chuang; C Y Dai; S C Chen; Z Y Lin; M Y Hsieh; L Y Wang; W Y Chang
Journal:  J Clin Microbiol       Date:  2000-08       Impact factor: 5.948

3.  Determination of hepatitis C virus genotypes in the United States by cleavase fragment length polymorphism analysis.

Authors:  D J Marshall; L M Heisler; V Lyamichev; C Murvine; D M Olive; G D Ehrlich; B P Neri; M de Arruda
Journal:  J Clin Microbiol       Date:  1997-12       Impact factor: 5.948

Review 4.  Current molecular methods for the detection of hepatitis C virus in high risk group population: A systematic review.

Authors:  Rushna Firdaus; Kallol Saha; Aritra Biswas; Provash Chandra Sadhukhan
Journal:  World J Virol       Date:  2015-02-12

Review 5.  Occult Infection with Hepatitis C Virus: Looking for Clear-Cut Boundaries and Methodological Consensus.

Authors:  Anna Wróblewska; Krzysztof Piotr Bielawski; Katarzyna Sikorska
Journal:  J Clin Med       Date:  2021-12-14       Impact factor: 4.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.