Literature DB >> 9095618

[An anesthesia machine malfunction due to dew condensation produced by abnormally high humidity in the electronically-controlled panel].

K Ushijima1, Y Yamada, Y Ikuta, M Sakamoto.   

Abstract

We present a case of anesthesia machine (NAR-KOMED 2CTM; N2C) malfunction caused by dew condensation. N2C is electronically controlled by an alarm-panel using the remote display. Abnormally high humidity in the operating room made dew condensation in the alarm-panel resulting in an electronic short circuit. Of great importance may be the damp proof improvement on medical equipment including anesthesia machines which have electronic circuits.

Mesh:

Year:  1997        PMID: 9095618

Source DB:  PubMed          Journal:  Masui        ISSN: 0021-4892