Literature DB >> 9087586

Measurement of intraventricular pressure and cardiac performance in the intact closed-chest anesthetized mouse.

J N Lorenz1, J Robbins.   

Abstract

To fully utilize the potential of newly developed mouse models with specific genetic mutations, it is necessary to study the functional consequences of genetic manipulation in the fully intact animal. To this end, the purpose of the present study was to develop and validate a methodology for the study of myocardial performance in the fully intact, closed-chest mouse. Left ventricular function was evaluated in euthyroid, hypothyroid, and hyperthyroid mice, animals with well-documented alterations in myocardial function. The mice were anesthetized and instrumented with polyethylene catheters in the right femoral artery and vein and with a Millar MIKRO-TIP transducer in the left ventricle via the right carotid artery. Structural and functional evidence suggested that the instrumentation procedure did not cause myocardial damage, valvular insufficiency, or aortic obstruction. Isovolumic indexes of myocardial contractility derived from the left ventricular pressure pulse and its first derivative demonstrated a 40% increase in contractility in the hyperthyroid animals and a 40% decrease in contractility in the hypothyroid animals. Similar differences in the indexes of relaxation were observed. Furthermore, isoproterenol dose-response relationships of these contractile parameters were blunted in the hypothyroid animals and augmented in the hyperthyroid animals compared with euthyroid control animals. Given the small size of the mouse and the high frequency of the cardiac cycle, these data demonstrate the feasibilty of combining a high-fidelity, microtip manometer with a high-speed data-acquisition system to obtain faithful recordings of cardiac performance in the fully intact mouse.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9087586     DOI: 10.1152/ajpheart.1997.272.3.H1137

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  30 in total

1.  Cardiac compartment-specific overexpression of a modified retinoic acid receptor produces dilated cardiomyopathy and congestive heart failure in transgenic mice.

Authors:  M C Colbert; D G Hall; T R Kimball; S A Witt; J N Lorenz; M L Kirby; T E Hewett; R Klevitsky; J Robbins
Journal:  J Clin Invest       Date:  1997-10-15       Impact factor: 14.808

2.  Impaired cardiac hypertrophic response in Calcineurin Abeta -deficient mice.

Authors:  Orlando F Bueno; Benjamin J Wilkins; Kevin M Tymitz; Betty J Glascock; Thomas F Kimball; John N Lorenz; Jeffery D Molkentin
Journal:  Proc Natl Acad Sci U S A       Date:  2002-03-19       Impact factor: 11.205

3.  Fibroblast growth factor 2 control of vascular tone.

Authors:  M Zhou; R L Sutliff; R J Paul; J N Lorenz; J B Hoying; C C Haudenschild; M Yin; J D Coffin; L Kong; E G Kranias; W Luo; G P Boivin; J J Duffy; S A Pawlowski; T Doetschman
Journal:  Nat Med       Date:  1998-02       Impact factor: 53.440

4.  Endothelial nitric oxide synthase overexpression attenuates congestive heart failure in mice.

Authors:  Steven P Jones; James J M Greer; Rien van Haperen; Dirk J Duncker; Rini de Crom; David J Lefer
Journal:  Proc Natl Acad Sci U S A       Date:  2003-04-03       Impact factor: 11.205

5.  Loss of the AE3 anion exchanger in a hypertrophic cardiomyopathy model causes rapid decompensation and heart failure.

Authors:  Nabeel J Al Moamen; Vikram Prasad; Ilona Bodi; Marian L Miller; Michelle L Neiman; Valerie M Lasko; Seth L Alper; David F Wieczorek; John N Lorenz; Gary E Shull
Journal:  J Mol Cell Cardiol       Date:  2010-11-04       Impact factor: 5.000

6.  Angiotensinergic stimulation of vascular endothelium in mice causes hypotension, bradycardia, and attenuated angiotensin response.

Authors:  Ramaswamy Ramchandran; Takanobu Takezako; Yasser Saad; Linda Stull; Bruno Fink; Hirotsugu Yamada; Sergey Dikalov; David G Harrison; Christine Moravec; Sadashiva S Karnik
Journal:  Proc Natl Acad Sci U S A       Date:  2006-12-05       Impact factor: 11.205

7.  Fibroblast growth factor-2 mediates pressure-induced hypertrophic response.

Authors:  J E Schultz; S A Witt; M L Nieman; P J Reiser; S J Engle; M Zhou; S A Pawlowski; J N Lorenz; T R Kimball; T Doetschman
Journal:  J Clin Invest       Date:  1999-09       Impact factor: 14.808

8.  Arterial Pressure Monitoring in Mice.

Authors:  Xin Zhao; David Ho; Shumin Gao; Chull Hong; Dorothy E Vatner; Stephen F Vatner
Journal:  Curr Protoc Mouse Biol       Date:  2011

9.  Cardiac stress test induced by dobutamine and monitored by cardiac catheterization in mice.

Authors:  Sebastián Dante Calligaris; Micaela Ricca; Paulette Conget
Journal:  J Vis Exp       Date:  2013-02-10       Impact factor: 1.355

10.  In vivo definition of cardiac myosin-binding protein C's critical interactions with myosin.

Authors:  Md Shenuarin Bhuiyan; Patrick McLendon; Jeanne James; Hanna Osinska; James Gulick; Bidur Bhandary; John N Lorenz; Jeffrey Robbins
Journal:  Pflugers Arch       Date:  2016-08-27       Impact factor: 3.657

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.