OBJECTIVES: To evaluate the functional and biological effect of implant-supported overdenture treatment in the lower jaw. METHODS AND MATERIALS: Thirty-two patients were consecutively treated with Astra Tech implants in the lower jaw for retaining overdentures. All implants had a diameter of 3.5 mm and all but two of the implants were longer than 10 mm. For the implant supported overdentures two methods of attachment were used, a bar or a ball.
RESULTS: One of 69 fixtures was lost during the 4-5 year observation period. The mean bone loss for all fixtures was less than 0.2 mm per year. Complications included 15 fractures of the ball attachment and 26 episodes of looseness of the matrices holding the screw in place. Patient satisfaction with the treatment of the lower jaw was high although 7 patients found that control of the upper denture was poor following treatment.
CONCLUSIONS: When the bone quality and quantity is sufficient, two implants can support an overdenture in the lower jaw, providing prosthesis which functions well.

Entities:  

Mesh:

Year:  1997        PMID: 9080751     DOI: 10.1016/s0300-5712(97)87699-3

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  2 in total

1.  Attachment systems for mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Jeong-Yol Lee; Sang-Wan Shin; S Ross Bryant
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

2.  Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Sang-Wan Shin; Jeong-Yol Lee
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.