Literature DB >> 9080245

Development of a portable closed-loop atracurium infusion system: systems methodology and safety issues.

D G Mason1, D A Linkens, N D Edwards, C S Reilly.   

Abstract

Safety of closed-loop drug infusion systems is an issue often raised as a matter of concern. As a result, many closed-loop control systems are reported in the literature merely as computer simulation studies and few ever reach the stage of physical realisation and formal clinical evaluation. We address the safety issues involved with such systems by describing the development of a portable closed-loop control system for atracurium-induced muscle relaxation. This is a safety-critical system particularly when applied to brain and eye surgery where movement could have serious deleterious effects. The benefits of closed-loop muscle relaxation in providing stable surgical operating conditions over a wide range of patient sensitivities while infusing the minimum amount of drug makes this a worthwhile aim and serves to demonstrate safety issues which are generally applicable to other closed-loop drug infusion systems. It is hoped that the described methodology will facilitate and encourage the clinical application of closed-loop drug infusion systems so that clinical staff and patients may receive the benefits of closed-loop drug therapy.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9080245     DOI: 10.1023/a:1016922427750

Source DB:  PubMed          Journal:  Int J Clin Monit Comput        ISSN: 0167-9945


  6 in total

1.  Hierarchical rule-based monitoring and fuzzy logic control for neuromuscular block.

Authors:  J S Shieh; S Z Fan; L W Chang; C C Liu
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

Review 2.  Automation of anaesthesia: a review on multivariable control.

Authors:  Jing Jing Chang; S Syafiie; Raja Kamil; Thiam Aun Lim
Journal:  J Clin Monit Comput       Date:  2014-06-25       Impact factor: 2.502

3.  Self-learning fuzzy control of atracurium-induced neuromuscular block during surgery.

Authors:  D G Mason; J J Ross; N D Edwards; D A Linkens; C S Reilly
Journal:  Med Biol Eng Comput       Date:  1997-09       Impact factor: 2.602

4.  Pain model and fuzzy logic patient-controlled analgesia in shock-wave lithotripsy.

Authors:  J S Shieh; L W Chang; M S Wang; W Z Sun; Y P Wang; Y P Yang
Journal:  Med Biol Eng Comput       Date:  2002-01       Impact factor: 2.602

5.  [Feedback control of muscle relaxation with a varying on-off controller using cisatracurium].

Authors:  B Pohl; R Hofmockel; O Simanski; K Wende; B P Lampe
Journal:  Anaesthesist       Date:  2004-01       Impact factor: 1.041

6.  Consumption of Cisatracurium in different age groups, using a closed loop computer controlled system.

Authors:  Shehzaad Joomye; Donglai Yan; Haiyun Wang; Guoqiang Zhou; Guolin Wang
Journal:  BMC Anesthesiol       Date:  2014-04-21       Impact factor: 2.217

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.