Literature DB >> 9076767

Dobutamine 99Tcm-MIBI SPET myocardial perfusion scintigraphy in the prediction of restenosis after percutaneous transluminal coronary angioplasty in patients unable to perform an exercise stress test.

A Elhendy1, M L Geleijnse, J R Roelandt, R T van Domburg, P R Nierop, J J Bax, J D Kasprzak, G M el-Said, M M Ibrahim, P M Fioretti.   

Abstract

After successful percutaneous transluminal coronary angioplasty (PTCA), restenosis occurs in a relatively high proportion of patients. Exercise thallium scintigraphy is a useful method for the detection of restenosis. In patients unable to exercise, dobutamine perfusion scintigraphy may represent a feasible alternative. However, its diagnostic accuracy in this clinical setting has not been evaluated. We studied 40 patients (29 males, 11 females) aged 57 +/- 9 years, at a mean of 185 +/- 80 days after successful PTCA with a high-dose dobutamine (up to 40 micrograms kg-1 min-1) stress test, in conjunction with 99Tcm-methoxyisobutyl isonitrile (99Tcm-MIBI) single photon emission tomography (SPET). Significant restenosis was defined as > or = 50% luminal diameter stenosis of a coronary segment with previous PTCA and was predicted on the basis of the occurrence of reversible perfusion defects in the corresponding territories. Reversible perfusion defects occurred in 20 of 29 arteries with and in 4 of 17 arteries without restenosis. The sensitivity of dobutamine MIBI for the detection of restenosis in arteries with previous PTCA was 69% (CI = 56-82), the specificity 76% (CI = 64-89), the positive predictive value 83% (CI = 73-94), the negative predictive value 59% (CI = 45-73) and accuracy 72% (CI = 59-85). The overall sensitivity of 99Tcm-MIBI SPET for the diagnosis of significant coronary stenosis (including arteries without previous PTCA) on a patient basis was 79% (CI = 67-92), the specificity 82% (CI = 70-94) and accuracy 80% (CI = 68-92). The sensitivity of 99Tcm-MIBI SPET was significantly higher than that of electrocardiography (79 vs 38%, P < 0.005). It is concluded that dobutamine 99Tcm-MIBI SPET is a useful method for the detection of restenosis after PTCA in patients unable to perform an exercise stress test.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9076767     DOI: 10.1097/00006231-199702000-00006

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  4 in total

1.  The grade of worsening of regional function during dobutamine stress echocardiography predicts the extent of myocardial perfusion abnormalities.

Authors:  A Elhendy; R T van Domburg; J J Bax; D Poldermans; P R Nierop; M L Geleijnse; J R Roelandt
Journal:  Heart       Date:  2000-01       Impact factor: 5.994

2.  Evaluation of restenosis and extent of coronary artery disease in patients with previous percutaneous coronary interventions by dobutamine stress real-time myocardial contrast perfusion imaging.

Authors:  A Elhendy; J M Tsutsui; E L O'Leary; F Xie; F Majeed; T R Porter
Journal:  Heart       Date:  2006-04-10       Impact factor: 5.994

3.  Dobutamine-atropine stress myocardial perfusion SPECT imaging in the diagnosis of graft stenosis after coronary artery bypass grafting.

Authors:  A Elhendy; R T van Domburg; J J Bax; P R Nierop; R Valkema; M L Geleijnse; J D Kasprzak; A F Liqui-Lung; J H Cornel; J R Roelandt
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

4.  Comparison of the Diagnostic Performance of Myocardial Perfusion Scintigraphy with and Without Attenuation Correction.

Authors:  Sira Vachatimanont; Sasitorn Sirisalipoch; Maythinee Chantadisai
Journal:  Mol Imaging Radionucl Ther       Date:  2022-06-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.