Literature DB >> 9075402

Electrochemical glucose and lactate sensors based on "wired" thermostable soybean peroxidase operating continuously and stably at 37 degrees C.

G Kenausis1, Q Chen, A Heller.   

Abstract

Following a recent report from our laboratory on a thermostable amperometric H2O2 sensor based on "wiring" soybean peroxidase, glucose and lactate sensors maintaining stable output under continuous operation at 37 degrees C for 12 and 8 days, respectively, were built. The vitreous carbon base of the sensor was coated with four polymer layers. The first was made by cross-linking thermostable soybean peroxidase and the redox polymer formed through complexing part of the rings of poly-(vinylpyridine) with [Os(bpy)2Cl]+/2+ (bpy = bipyridine) and quaternizing part of the rings with bromoethylamine. The second was an insulating and H2O2 transport controlling cellulose acetate layer. The third was an immobilized glucose oxidase or lactate oxidase layer. The fourth was a substrate transport controlling cellulose acetate layer In the case of the glucose sensor, the current output was independent of potential between -0.2 and +0.3 V (vs SCE), and the response time (t10/90) was < 2 min when the concentration was raised from 0 to 5 mM glucose. The current was independent of the O2 partial pressure above 15 Torr. The sensor was relatively insensitive to motion and to interferants. Changing the rotation speed of the electrode from 50 to 2500 rpm increased the current by < 10%. At a glucose concentration of 4 mM, the addition of 0.1 mM ascorbate decreased the current by < 1%. The operational stability was glucose oxidase loading dependent. Though the current decreased by 85% after 100 h of operation at 37 degrees C when the 3-mm-diameter electrode was loaded with only 1.3 micrograms of glucose oxidase, it decreased by < 1% after such operation when loaded with 52 micrograms of the enzyme. Similar results were obtained for the lactate sensor, with the exception of a more noticeable oxygen concentration dependence of the lactate response at low oxygen concentrations.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9075402     DOI: 10.1021/ac961083y

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Injectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring.

Authors:  Hideaki Shibata; Yun Jung Heo; Teru Okitsu; Yukiko Matsunaga; Tetsuro Kawanishi; Shoji Takeuchi
Journal:  Proc Natl Acad Sci U S A       Date:  2010-10-04       Impact factor: 11.205

2.  Modulation of fibroblast inflammatory response by surface modification of a perfluorinated ionomer.

Authors:  Thelma I Valdes; Winston Ciridon; Buddy D Ratner; James D Bryers
Journal:  Biointerphases       Date:  2011-06       Impact factor: 2.456

3.  Multiscattering-enhanced optical biosensor: multiplexed, non-invasive and continuous measurements of cellular processes.

Authors:  Volodymyr B Koman; Christian Santschi; Olivier J F Martin
Journal:  Biomed Opt Express       Date:  2015-06-05       Impact factor: 3.732

4.  Mixed monolayers of ferrocenylalkanethiol and encapsulated horseradish peroxidase for sensitive and durable electrochemical detection of hydrogen peroxide.

Authors:  Yong Peng; Dianlu Jiang; Lei Su; Lin Zhang; Ming Yan; Juanjuan Du; Yunfeng Lu; You-Nian Liu; Feimeng Zhou
Journal:  Anal Chem       Date:  2009-12-15       Impact factor: 6.986

5.  Printed, Flexible Lactate Sensors: Design Considerations Before Performing On-Body Measurements.

Authors:  Margaret E Payne; Alla Zamarayeva; Veronika I Pister; Natasha A D Yamamoto; Ana Claudia Arias
Journal:  Sci Rep       Date:  2019-09-23       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.