Literature DB >> 9074985

Shunt and ventilation-perfusion distribution during partial liquid ventilation in healthy piglets.

E A Mates1, J Hildebrandt, J C Jackson, P Tarczy-Hornoch, M P Hlastala.   

Abstract

Replacing gas in the lung with perfluorocarbon fluids (PFC) and periodically ventilating with a gas [partial liquid ventilation (PLV)] has been shown to improve oxygenation in models of respiratory distress syndrome. We hypothesized that the addition of PFC to healthy lungs would result in shunt, diffusion impairment, and increased ventilation-perfusion (VA/Q) heterogeneity. Previously, Mates et al. showed that O2 shunt and arterial-alveolar CO2 difference increased linearly with dose in piglets given graded intratracheal doses of PFC (10, 20, and 30 ml/kg followed by mechanical ventilation with 100% O2) (E.A. Mates, J. C. Jackson, J. Hildebrandt, W. E. Truog, T. A. Standaert, and M. P. Hlastala. In: Oxygen Transport to Tissue XVI, 1994, p. 427-435). Here we report VA/Q distribution in the same animals, showing a 50% increase in VA/Q heterogeneity during PLV independent of PFC dose. Ventilation heterogeneity was the major factor in this increase, and there was no significant change in dead space ventilation. We also report on five animals given a single 20 ml/kg dose of PFC and followed for 3 h. They showed an increase in shunt during PLV but no change in arterial-alveolar CO2 difference.

Entities:  

Mesh:

Year:  1997        PMID: 9074985     DOI: 10.1152/jappl.1997.82.3.933

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  6 in total

1.  Intranasal perfluorochemical spray for preferential brain cooling in sheep.

Authors:  Marla R Wolfson; Daniel J Malone; Jichuan Wu; John Hoffman; Allan Rozenberg; Thomas H Shaffer; Denise Barbut
Journal:  Neurocrit Care       Date:  2008       Impact factor: 3.210

2.  Changes in FiO2 affect PaO2 with minor alterations in cerebral concentration of oxygenated hemoglobin during liquid ventilation in healthy piglets.

Authors:  Wolfram Burkhardt; Hans Proquitté; Susann Krause; Roland R Wauer; Mario Rüdiger
Journal:  Intensive Care Med       Date:  2004-01-14       Impact factor: 17.440

3.  [Preserved spontaneous breathing during partial liquid ventilation. Results of experimental animal studies and their clinical implications].

Authors:  H D Hummler; F Pohlandt; A Schulze
Journal:  Anaesthesist       Date:  2003-12       Impact factor: 1.041

4.  Time-dependency of improvements in arterial oxygenation during partial liquid ventilation in experimental acute respiratory distress syndrome.

Authors:  M Max; R Kuhlen; R Dembinski; R Rossaint
Journal:  Crit Care       Date:  2000-02-10       Impact factor: 9.097

5.  Comparison Study of Airway Reactivity Outcomes due to a Pharmacologic Challenge Test: Impulse Oscillometry versus Least Mean Squared Analysis Techniques.

Authors:  Elena Rodriguez; Charrell M Bullard; Milena H Armani; Thomas L Miller; Thomas H Shaffer
Journal:  Pulm Med       Date:  2013-04-11

6.  The use of chilled condensers for the recovery of perfluorocarbon liquid in an experimental model of perfluorocarbon vapour loss during neonatal partial liquid ventilation.

Authors:  Kimble R Dunster; Mark W Davies; John F Fraser
Journal:  Biomed Eng Online       Date:  2007-05-31       Impact factor: 2.819

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.